External validation of severity scoring systems for acute renal failure using a multinational database

被引:103
作者
Uchino, Shigehiko [1 ]
Bellomo, Rinaldo
Morimatsu, Hiroshi
Morgera, Stanislao
Schetz, Miet
Tan, Ian
Bouman, Catherine
Macedo, Ettiene
Gibney, Noel
Tolwani, Ashita
Doig, Gordon S.
van Straaten, Heleen Oudemans
Ronco, Claudio
Kellum, John A.
机构
[1] Austin Hosp, Dept Intens Care, Melbourne, Vic 3084, Australia
[2] Austin Hosp, Dept Med, Melbourne, Vic 3084, Australia
[3] Univ Hosp Charite, Dept Nephrol, Berlin, Germany
[4] Univ Ziekenhuis Gasthuisberg, Dienst Intens Geneeskunde, Louvain, Belgium
[5] Singapore Gen Hosp, Dept Intens Care Med, Singapore 0316, Singapore
[6] Univ Amsterdam, Acad Med Ctr, Adult Intens Care Unit, NL-1105 AZ Amsterdam, Netherlands
[7] Univ Sao Paulo, Sch Med, Div Nephrol, Sao Paulo, Brazil
[8] Univ Alberta, Div Crit Care Med, Edmonton, AB, Canada
[9] Univ Alabama Birmingham, Dept Med, Div Nephrol, Birmingham, AL 35294 USA
[10] Royal N Shore Hosp, Dept Intens Care Med, Sydney, NSW, Australia
[11] Onze Lieve Vrouw Hosp, Intens Care Unit, Vicenza, Italy
[12] St Bortolo Hosp, Vicenza, Italy
[13] Univ Pittsburgh, Sch Med, Dept Crit Care Med, Pittsburgh, PA USA
关键词
acute kidney failure; critical illness; severity score; renal replacement therapy; hemodialysis; hemofiltration;
D O I
10.1097/01.CCM.0000172279.66229.07
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. Several different severity scoring systems specific to acute renal failure have been proposed. However, most validation studies of these scoring systems were conducted in a single center or in a small number of centers, often the same ones used for their development. Therefore, it is not known whether such severity scoring systems may be widely applied. Design: Prospective clinical investigation. Setting: Intensive care units. Patients: One thousand seven hundred and forty-two intensive care unit patients with acute renal failure who were either treated with renal replacement therapy or fulfilled predefined criteria. Interventions: Demographic and clinical information and outcomes were measured. Measurements and Main Results. Scores for four acute renal failure-specific scoring systems and two general scoring systems (Simplified Acute Physiology Score II and Sequential Organ Failure Assessment) were calculated, and their discrimination and calibration were tested with receiver operating characteristic curves and Hosmer-Lemeshow goodness-of fit-tests. For the receiver operating characteristic curves, blood lactate levels were also used as a reference. All scores had an area under the receiver operating characteristic curve < 0.7 (Mehta 0.670, Liano 0.698, Chertow 0.610, Paganini 0.643, Simplified Acute Physiology Score II 0.645, Sequential Organ Failure Assessment 0.675, lactate 0.639). For scores that can calculate predicted mortality, the Hosmer-Lemeshow goodness-of-fit test showed poor calibration. Conclusions: None of the scoring systems tested had a high level of discrimination or calibration to predict mortality for patients with acute renal failure when tested in a broad cohort of patients from multiple countries. A large, multiple-center database might be needed to improve the discrimination and calibration of acute renal failure scoring system.
引用
收藏
页码:1961 / 1967
页数:7
相关论文
共 32 条
[1]   Anaritide in acute tubular necrosis [J].
Allgren, RL ;
Marbury, TC ;
Rahman, SN ;
Weisberg, LS ;
Fenves, AZ ;
Lafayette, RA ;
Sweet, RM ;
Genter, FC ;
Kurnik, BRC ;
Conger, JD ;
Sayegh, MH .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (12) :828-834
[2]   Acute renal failure in intensive care units - Causes, outcome, and prognostic factors of hospital mortality: A prospective, multicenter study [J].
Brivet, FG ;
Kleinknecht, DJ ;
Loirat, P ;
Landais, PJM ;
Bedock, B ;
Bleichner, G ;
Richard, C ;
Coste, F ;
BrunBuisson, C ;
Sicot, C ;
Tenaillon, A ;
Gajdos, P ;
Blin, F ;
Saulnier, F ;
Agostini, MM ;
Nicolas, F ;
FeryLemonnier, E ;
Staikowski, F ;
Carlet, J ;
Guivarch, G ;
Fraisse, F ;
Ricome, J ;
Tempe, JD ;
Mezzarobba, P .
CRITICAL CARE MEDICINE, 1996, 24 (02) :192-198
[3]   THE ASSESSMENT OF RISK-FACTORS IN 462 PATIENTS WITH ACUTE RENAL-FAILURE [J].
BULLOCK, ML ;
UMEN, AJ ;
FINKELSTEIN, M ;
KEANE, WF .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1985, 5 (02) :97-103
[4]  
Chertow GM, 1998, J AM SOC NEPHROL, V9, P692
[5]   Acute renal failure in the ICU:: risk factors and outcome evaluated by the SOFA score [J].
de Mendonça, A ;
Vincent, JL ;
Suter, PM ;
Moreno, R ;
Dearden, NM ;
Antonelli, M ;
Takala, J ;
Sprung, C ;
Cantraine, F .
INTENSIVE CARE MEDICINE, 2000, 26 (07) :915-921
[6]  
Douma CE, 1997, J AM SOC NEPHROL, V8, P111
[7]   Predicting patient outcome from acute renal failure comparing three general severity of illness scoring systems [J].
Fiaccadori, E ;
Maggiore, U ;
Lombardi, M ;
Leonardi, S ;
Rotelli, C ;
Borghetti, A .
KIDNEY INTERNATIONAL, 2000, 58 (01) :283-292
[8]  
Halstenberg WK, 1997, CLIN NEPHROL, V47, P81
[9]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[10]   Multicenter clinical trial of recombinant human insulin-like growth factor I in patients with acute renal failure [J].
Hirschberg, R ;
Kopple, J ;
Lipsett, P ;
Benjamin, E ;
Minei, J ;
Albertson, T ;
Munger, M ;
Metzler, M ;
Zaloga, G ;
Murray, M ;
Lowry, S ;
Conger, J ;
McKeown, W ;
O'Shea, M ;
Baughman, R ;
Wood, K ;
Haupt, M ;
Kaiser, R ;
Simms, H ;
Warnock, D ;
Summer, W ;
Hintz, R ;
Myers, B ;
Haenftling, K ;
Capra, W ;
Pike, M ;
Guler, HP .
KIDNEY INTERNATIONAL, 1999, 55 (06) :2423-2432