Effect of vent openings and insect screens on greenhouse ventilation

被引:87
作者
Katsoulas, N
Bartzanas, T
Boulard, T
Mermier, M
Kittas, C
机构
[1] INRA, URIH 400, F-06903 Sophia Antipolis, France
[2] INRA, Unite Bioclimatol, F-84914 Avignon 9, France
关键词
D O I
10.1016/j.biosystemseng.2005.01.001
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The objective of this work was to experimentally investigate the influence of vent type (side, roof or both) and of an anti-aphid insect screen used to prevent insect intrusion on the ventilation rate of a round arch with vertical side walls, polyethylene covered greenhouse. The greenhouse was equipped with two side roll-up vents and a flap roof vent located at the University of Thessaly near Velestino in the continental area of Eastern Greece. Microclimate variables as well as the airflow rate were measured during summer. Two measuring methods were used for the determination of ventilation rate: (a) the decay rate `tracer gas' method, using nitrous oxide N2O as tracer gas, and (b) the greenhouse 'energy balance' method. In order to study the effect of vent type on ventilation rate, in a greenhouse with an anti-aphid insect screen in the vent openings, airflow was determined during periods with ventilation being performed by: (i) roof, (ii) side or (iii) both roof and side vents. Furthermore, in order to study the effect of insect proof screen on airflow, measurements were also carried out during periods that ventilation was performed by side vents without a screen in the openings. A good correlation was found between the air exchange rate values calculated using the two methods, with the values obtained by the tracer gas method being slightly lower than those obtained by the energy balance method. Furthermore, the data of ventilation rate obtained by the tracer gas method fitted better to the model used for the prediction of ventilation rate. In addition, the use of anti-aphid screen in vent openings caused a 33% reduction in greenhouse ventilation rate. From greenhouse ventilation performance point of view, it was found that the most effective vent configuration was the combination of roof and side vents, followed by side vents only (46% reduction in ventilation), while the least effective was roof vent (71 % reduction ventilation). (c) 2006 Silsoe Research Institute. All rights reserved Published by Elsevier Ltd.
引用
收藏
页码:427 / 436
页数:10
相关论文
共 34 条
[1]  
*ASAE, 1999, EP4063 ANSI ASAE, P679
[2]  
*ASHRAE, 1993, ASHRAE HDB FUND, V14
[3]   Greenhouse ventilation rate: Theory and measurement with tracer gas techniques [J].
Baptista, FJ ;
Bailey, BJ ;
Randall, JM ;
Meneses, JF .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 72 (04) :363-374
[4]   Effect of vent arrangement on windward ventilation of a tunnel greenhouse [J].
Bartzanas, T ;
Boulard, T ;
Kittas, C .
BIOSYSTEMS ENGINEERING, 2004, 88 (04) :479-490
[5]   MODELING OF AIR EXCHANGE-RATE IN A GREENHOUSE EQUIPPED WITH CONTINUOUS ROOF VENTS [J].
BOULARD, T ;
BAILLE, A .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1995, 61 (01) :37-47
[6]   Mean and turbulent air flows and microclimatic patterns in an empty greenhouse tunnel [J].
Boulard, T ;
Wang, S ;
Haxaire, R .
AGRICULTURAL AND FOREST METEOROLOGY, 2000, 100 (2-3) :169-181
[7]   Experimental and numerical studies on the heterogeneity of crop transpiration in a plastic tunnel [J].
Boulard, T ;
Wang, S .
COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2002, 34 (1-3) :173-190
[8]   Natural ventilation performance of six greenhouse and tunnel types [J].
Boulard, T ;
Feuilloley, P ;
Kittas, C .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1997, 67 (04) :249-266
[9]  
De Jong T, 1990, THESIS WAGENINGEN U
[10]   Natural ventilation and microclimatic performance of a large-scale banana greenhouse [J].
Demrati, H ;
Boulard, T ;
Bekkaoui, A ;
Bouirden, L .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 2001, 80 (03) :261-271