Noninvasive Doppler tissue measurement of pulmonary artery compliance in children with pulmonary hypertension

被引:31
作者
Dyer, K
Lanning, C
Das, B
Lee, PF
Ivy, DD
Valdes-Cruz, L
Shandas, R
机构
[1] Univ Colorado, Cardiovasc Flow & Imaging Res Lab, Hlth Sci Ctr, Childrens Hosp,Dept Pediat,Div Pediat Cardiol, Denver, CO 80218 USA
[2] Univ Colorado, Dept Mech Engn, Boulder, CO 80309 USA
关键词
D O I
10.1016/j.echo.2005.11.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Methods: Dynamic compliance (C-dyn) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. C-dyn was calculated as: [(D-s-D-d)/(D(d)xP(s))]x 10(4) where D-s = systolic diameter, D-d = diastolic diameter, and P-s = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects C-dyn was also measured in an additional 13 patients undergoing reactivity studies. Results: Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, C-dyn. calculated by CMM DTI agreed with C-dyn calculated using invasive techniques (23.4 +/- 16.8 vs 29.1 +/- 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower C-dyn, values than control subjects (P < .01). C-dyn values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress-strain behavior of these arteries. Reactivity in C-dyn agreed with reactivity measured using impedance techniques. Conclusion: The C-dyn method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension.
引用
收藏
页码:403 / 412
页数:10
相关论文
共 19 条
[1]   Possibilities and impossibilities in the evaluation of pulmonary vascular disease in congenital heart defects [J].
Berger, RMF .
EUROPEAN HEART JOURNAL, 2000, 21 (01) :17-27
[2]   Inhaled nitric oxide to test the vasodilator capacity of the pulmonary vascular bed in children with long-standing pulmonary hypertension and congenital heart disease [J].
Berner, M ;
Beghetti, M ;
SpahrSchopfer, I ;
Oberhansli, I ;
Friedli, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (07) :532-+
[3]  
BONNEFOUS O, 1996, IEEE ULTRASON S, V2, P1059
[4]  
Das BB, 2004, PEDIATR RES, V55, p51A
[5]   Arterial pulse wave velocity with tissue Doppler imaging [J].
Eriksson, A ;
Greiff, E ;
Loupas, T ;
Persson, M ;
Pesque, P .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (05) :571-580
[6]   Color Doppler tissue imaging in assessing the elastic properties of the aorta and in predicting coronary artery disease [J].
Eryol, NK ;
Topsakal, R ;
Çiçek, Y ;
Abaci, A ;
Oguzhan, A ;
Basar, E ;
Ergin, A .
JAPANESE HEART JOURNAL, 2002, 43 (03) :219-230
[7]  
HOFFMAN J I E, 1972, Birth Defects Original Article Series, V8, P9
[8]   THE RELATIONSHIP BETWEEN PULMONARY-ARTERY PRESSURE AND PULMONARY-ARTERY DIAMETER IN PULMONARY-HYPERTENSION [J].
MOORE, NR ;
SCOTT, JP ;
FLOWER, CDR ;
HIGENBOTTAM, TW .
CLINICAL RADIOLOGY, 1988, 39 (05) :486-489
[9]  
PASIERSKI TJ, 1990, CHEST, V104, P1080
[10]   Characterization of peripheral arterial wall motion by Doppler tissue echography:: A validation study [J].
Pelle, G ;
Pascal, O ;
Adnot, S ;
Gueret, P ;
Dubois-Randé, JL ;
Belhassen, L .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (10) :1218-1225