Systematical evaluation of the effects of sample collection procedures on low-molecular-weight serum/plasma proteome profiling

被引:189
作者
Hsieh, Sen-Yung [1 ]
Chen, Ren-Kung [1 ]
Pan, Yi-Hsin [1 ]
Lee, Hai-Lun [1 ]
机构
[1] Chang Gung Mem Hosp, Clin Proteom Ctr, Taoyuan, Taiwan
关键词
magnetic bead-based MALDI-TOF-MS; plasma proteome; sampling procedure; SELDI-TOF-MS; serum proteome;
D O I
10.1002/pmic.200500535
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Blood is an ideal source for biomarker discovery. However, little has been done to address the effects of sampling, handling and storage procedures on serum/plasma proteomes. We used magnetic bead-based MALDI-TOF MS to systematically evaluate the influence of each procedure on low-molecular-weight serum/plasma proteome profiling on the basis of the whole spectra. We found that sampling procedures, including the selection of blood collection tubes and anticoagulants, variations in dotting time or time lag before centrifugation, and hemolysis, displayed significant effects on the proteomes. Moreover, serum and plasma were mutually incompatible for proteome comparison. By contrast, overnight fasting, handling procedures, including centrifugation speeds (1500 x g vs. 3000 x g) or time (15 min vs. 30 min), and storage conditions, such as at 4 degrees C or 25 degrees C for up to 24 h or at -80 degrees C for up to 3 months, and repeated freeze/thaw of up to ten cycles, had relatively minor effects on the proteomes based upon our analysis of about 100 peaks. We concluded that low-molecular-weight serum/plasma proteomes were diversely affected by sampling, handling and storage with most change from variations of sampling procedures. We therefore suggest the necessity of standardizing sampling procedure for proteome comparison and biomarker discovery.
引用
收藏
页码:3189 / 3198
页数:10
相关论文
共 32 条
[1]  
Adam BL, 2002, CANCER RES, V62, P3609
[2]   Toward a human blood serum proteome - Analysis by multidimensional separation coupled with mass spectrometry [J].
Adkins, JN ;
Varnum, SM ;
Auberry, KJ ;
Moore, RJ ;
Angell, NH ;
Smith, RD ;
Springer, DL ;
Pounds, JG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (12) :947-955
[3]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[4]   The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[5]  
[Anonymous], 2005, BIOTECHNIQUES, DOI DOI 10.2144/05386SU07
[6]   Influences of blood sample processing on low-molecular-weight proteome identified by surface-enhanced laser desorption/ionization mass spectrometry [J].
Banks, RE ;
Stanley, AJ ;
Cairns, DA ;
Barrett, JH ;
Clarke, P ;
Thompson, D ;
Selby, PJ .
CLINICAL CHEMISTRY, 2005, 51 (09) :1637-1649
[7]   Standardized approach to proteome profiling of human serum based on magnetic bead separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Baumann, S ;
Ceglarek, U ;
Fiedler, GM ;
Lembcke, J ;
Leichtle, A ;
Thiery, J .
CLINICAL CHEMISTRY, 2005, 51 (06) :973-980
[8]  
Burtis C A, 1999, Textbook of Clinical Chemistry, V3rd
[9]  
Celis JE, 2003, MOL CELL PROTEOMICS, V2, P367, DOI 10.1074/mcp.E300003-MCP200
[10]   Proteomic patterns in serum and identification of ovarian cancer [J].
Diamandis, EP .
LANCET, 2002, 360 (9327) :170-170