摘要
Dissolved gas analysis (DGA) of transformer oil is one of the most effective power transformer condition monitoring tools. There are many interpretation techniques for DGA results however all these techniques rely on personnel experience more than analytical formulation. As a result, various interpretation techniques do not necessarily lead to the same conclusion for the same oil sample. Furthermore, significant number of DGA results fall outside the proposed codes of the current based-ratio interpretation techniques and cannot be diagnosed by these methods. Moreover, ratio methods fail to diagnose multiple fault conditions due to the mixing up of produced gases. To overcome these limitations, this paper introduces a new fuzzy logic approach to reduce dependency on expert personnel and to aid in standardizing DGA interpretation techniques. The approach relies on incorporating all existing DGA interpretation techniques into one expert model. DGA results of 2000 oil samples that were collected from different transformers of different rating and different life span are used to establish the model. Traditional DGA interpretation techniques are used to analyze the collected DGA results to evaluate the consistency and accuracy of each interpretation technique. Results of this analysis were then used to develop the proposed fuzzy logic model.
引用
收藏
页码:2343 / 2349
页数:7
相关论文
共 27 条
[1]
A New Approach to Identify Power Transformer Criticality and Asset Management Decision Based on Dissolved Gas-in-Oil Analysis [J].
Abu-Siada, A. ;
Islam, S. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (03) :1007-1012
[2]
A Novel Fuzzy-Logic Approach for Furan Estimation in Transformer Oil [J].
Abu-Siada, A. ;
Lai, Sin P. ;
Islam, Syed M. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (02) :469-474
[3]
A Novel Online Technique to Detect Power Transformer Winding Faults [J].
Abu-Siada, A. ;
Islam, Syed .
IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (02) :849-857
[4]
Abu-Siada A, 2010, IEEE PES GEN M, P1, DOI DOI 10.1109/PES.2010.5589789
[5]
[Anonymous], 1992, C571041991 IEEE
[6]
[Anonymous], 2008, IEEE STD C37110 2007, pC1
[7]
[Anonymous], 2005, P IEEE PES TRANSM DI
[8]
[Anonymous], 1997, 60599 IEC
[9]
[Anonymous], 1995, 621995 IEEE
[10]
Effective diagnostics for oil-filled equipment [J].
Arakelian, VG .
IEEE ELECTRICAL INSULATION MAGAZINE, 2002, 18 (06) :26-38