Iontophoretic transdermal absorption of insulin and calcitonin in rats with newly-devised switching technique and addition of urea

被引:33
作者
Tomohira, Y
Machida, Y
Onishi, H
Nagai, T
机构
[1] HOSHI UNIV,DEPT CLIN PHARM,SHINAGAWA KU,TOKYO 142,JAPAN
[2] HOSHI UNIV,DEPT PHARMACEUT,SHINAGAWA KU,TOKYO 142,JAPAN
关键词
iontophoresis; switching technique; transdermal absorption; insulin; calcitonin; urea; depolarization; dermal irritation;
D O I
10.1016/S0378-5173(97)00171-3
中图分类号
R9 [药学];
学科分类号
1007 [药学];
摘要
The effect of urea and reversing polarity of electrodes (switching technique) in iontophoresis was investigated in order to get a better transdermal absorption of peptide drugs: insulin and calcitonin, and to reduce dermal irritation caused by the iontophoresis. Two cells with an electrode were set on the hair-removed abdominal skin of diabetic or oophorectomized rats. After putting peptide solution into the anode side or both of the cells, an electric current with pulsed rectangular wave form (4 kHz, 50% duty) was passed through the skin for 2 h at 0.075 mh cm(-2) (insulin) and for 50 min or 2 h at 0.015 mA cm(-2) (calcitonin). Absorption of insulin and calcitonin was estimated from the reduction of glucose and calcium levels in the plasma of the rats, respectively. When the polarity of electrodes was reversed at intervals of 20 min for insulin and 25 min for calcitonin, absorption of the drug was effectively enhanced. The addition of urea to the insulin solution together with the switching technique brought about a remarkably facilitated absorption of insulin. Moreover, comparison of the skin conditions between switching and non-switching experiments suggested that irritation of skin could be reduced by employment of the switching iontophoresis. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:231 / 239
页数:9
相关论文
共 9 条
[1]
CONTROL OF BLOOD-GLUCOSE LEVELS IN ALLOXAN-DIABETIC RABBITS BY IONTOPHORESIS OF INSULIN [J].
KARI, B .
DIABETES, 1986, 35 (02) :217-221
[2]
LIU JC, 1988, INT J PHARM, V44, P197
[3]
Reverse iontophoresis - Parameters determining electroosmotic flow .1. pH and ionic strength [J].
Santi, P ;
Guy, RH .
JOURNAL OF CONTROLLED RELEASE, 1996, 38 (2-3) :159-165
[4]
SKIN ALTERATION AND CONVECTIVE SOLVENT FLOW EFFECTS DURING IONTOPHORESIS .1. NEUTRAL SOLUTE TRANSPORT ACROSS HUMAN SKIN [J].
SIMS, SM ;
HIGUCHI, WI ;
SRINIVASAN, V .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1991, 69 (02) :109-121
[5]
IONTOPHORESIS OF POLYPEPTIDES - EFFECT OF ETHANOL PRETREATMENT OF HUMAN SKIN [J].
SRINIVASAN, V ;
SU, MH ;
HIGUCHI, WI ;
BEHL, CR .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1990, 79 (07) :588-591
[6]
STEPHEN RL, 1984, BIOMED BIOCHIM ACTA, V43, P553
[7]
TERZO SD, 1989, PHARM RES, V6, P85
[8]
THYSMAN S, 1995, SKIN PHARMACOL, V8, P229
[9]
TOMOHIRA Y, 1989, P 109 ANN M PHARM 2, P129