Reliability and comparability of the accelerometer as a measure of muscular power

被引:45
作者
Thompson, CJ
Bemben, MG
机构
[1] Univ Oklahoma, Dept Hlth & Sport Sci, Neuromuscular Res Lab, Norman, OK 73019 USA
[2] Univ Kansas, Dept Hlth Phys Educ & Recreat, Lawrence, KS 66045 USA
关键词
power assessment; technology; validity;
D O I
10.1097/00005768-199906000-00020
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: The purpose of this study was to determine the effectiveness of using accelerometry as a reliable measure of upper body muscular power and its comparability with other conventional measurement tools. Methods: Thirty men, aged 19 to 25 yr, gave informed written consent before performing a one-repetition maximum (1RM) bench press on a linear bench press apparatus. Three trials of 60% 1RM were then performed at 1-min intervals and the entire procedure was repeated the following day. Each trial was analyzed for average power (AP), average velocity (AV), and total displacement (TD) by three instruments: a uni-axial piezoresistive accelerometer (ICS Sensors Model 3145, Milpitas, CA) mounted on the Cybex Smith Press (Owatonna, MN) apparatus, a 17-mm video camera that recorded the lift, and an infrared photocell and timer system arranged to analyze a 20-cm segment of the lift. Acceleration data collected at 60 Hz obtained a direct measurement of force and an integrated measure of velocity to calculate muscular power. Results: Repeated measures ANOVA and intraclass correlation coefficients indicated high trial to trial reliability (r = 0.99) for all measurement variables. Film PLP was significantly greater (P less than or equal to 0.05) than the accelerometer AP and the photocell AP in the 20-cm segment (356.6 +/- 94.8 W vs 335.5 +/- 97.7 W, and 342.0 +/- 97.2 W, respectively). Also, significant mean differences (P less than or equal to 0.05) between the accelerometer and film measurements existed for AP (246.0 +/- 70.2 W vs 286.1 +/- 83.6 W), AV (44.4 +/- 9.2 cm.s(-1) vs 51.3 +/- 12.3 cm.s(-1)) and TD (43.2 +/- 7.9 cm vs 47.4 +/- 7.4 cm) when examined over the entire lift, but there were significant correlations between the two methods (AP, r = 0.95; AV, r = 0.98; TD, r = 0.93). Conclusions: These results suggest that although minor data acquisition errors were present, accelerometers can provide a reliable and versatile means to assess muscle power.
引用
收藏
页码:897 / 902
页数:6
相关论文
共 18 条
[1]   MOMENT AND POWER-GENERATION DURING MAXIMAL KNEE EXTENSIONS PERFORMED AT LOW AND HIGH SPEEDS [J].
AAGAARD, P ;
SIMONSEN, EB ;
TROLLE, M ;
BANGSBO, J ;
KLAUSEN, K .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1994, 69 (05) :376-381
[2]   EFFECTS OF DIFFERENT STRENGTH TRAINING REGIMES ON MOMENT AND POWER-GENERATION DURING DYNAMIC KNEE EXTENSIONS [J].
AAGAARD, P ;
SIMONSEN, EB ;
TROLLE, M ;
BANGSBO, J ;
KLAUSEN, K .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1994, 69 (05) :382-386
[3]  
*AM COLL SPORTS ME, 1991, GUID EX TEST PRESCR, P48
[4]  
[Anonymous], 1991, PHYSL TESTING HIGH P
[5]  
BEMBEN M, 1991, J APPL SPORT SCI RES, V5, P162
[6]  
BEMBEN MG, 1997, GERONTOLOGIST, V37, P97
[7]   A DYNAMOMETER FOR EVALUATION OF DYNAMIC MUSCLE WORK [J].
BOSCO, C ;
BELLI, A ;
ASTRUA, M ;
TIHANYI, J ;
POZZO, R ;
KELLIS, S ;
TSARPELA, O ;
FOTI, C ;
MANNO, R ;
TRANQUILLI, C .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 70 (05) :379-386
[8]   AN INVITRO SIMULATION STUDY OF IMPULSIVE FORCE TRANSMISSION ALONG THE LOWER SKELETAL EXTREMITY [J].
CHU, ML ;
YAZDANIARDAKANI, S ;
GRADISAR, IA ;
ASKEW, MJ .
JOURNAL OF BIOMECHANICS, 1986, 19 (12) :979-&
[9]  
Cohen J., 1988, STAT POWER ANAL BEHA, DOI 10.1016/C2013-0-10517-X
[10]   EFFECTS OF VELOCITY OF ISOKINETIC TRAINING ON STRENGTH, POWER, AND QUADRICEPS MUSCLE-FIBER CHARACTERISTICS [J].
EWING, JL ;
WOLFE, DR ;
ROGERS, MA ;
AMUNDSON, ML ;
STULL, GA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1990, 61 (1-2) :159-162