Incidents relating to arterial cannulation as identified in 7525 reports submitted to the Australian Incident Monitoring Study (AIMS-ICU)

被引:41
作者
Durie, M
Beckmann, U
Gillies, DM
机构
[1] John Hunter Hosp, Div Anaesthesia Intens Care & Pain Management, Newcastle, NSW 2300, Australia
[2] Tweed Heads Hosp, Dept Crit Care, Tweed Heads, NSW, Australia
关键词
ADVERSE EFFECTS : arterial line; arterial cannulae; critical care; incident rnonitoring; INTENSIVE CARE : patient safety; quality assurance; risk factors;
D O I
10.1177/0310057X0203000111
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Arterial cannulation is frequently used in the critical care environment. Literature focuses on insertion techniques and complications. This report utilized data from the Australian Incident Monitoring Study (AIMS-ICU) national database to identify common problems and contributing factors associated with the use and maintenance of arterial lines. A review of narratives, keywords and contributing factors yielded 251 reports outlining 376 incidents. Of these, 15% describing line insertion problems, 66% line use and maintenance problems and 19% patient injuries. Inadequate line securing, accidental line dislodgement, incorrect set-up, distal ischaemia and infection featured prominently. As a result of the incident, 49% of patients involved suffered no ill effect, 28% minor physiological complications and 15% suffered major adverse effects. Multiple contributing factors were selected for each report, with lack of knowledge, rule-based errors, high unit activity, and lack of support staff or supervision selected most frequently. This study, highlights the need to employ, meticulous insertion technique, line set-up, securing, frequent line assessment and the early removal of lines no longer essential to patient care. Support and education of staff as well as the development of protocols are important for the safe use of arterial lines.
引用
收藏
页码:60 / 65
页数:6
相关论文
共 20 条
[1]   INFECTIONS CAUSED BY ARTERIAL CATHETERS USED FOR HEMODYNAMIC MONITORING [J].
BAND, JD ;
MAKI, DG .
AMERICAN JOURNAL OF MEDICINE, 1979, 67 (05) :735-741
[2]   Problems associated with nursing staff shortage: An analysis of the first 3600 incident reports submitted to the Australian incident monitoring study (AIMS-ICU) [J].
Beckmann, U ;
Baldwin, I ;
Durie, M ;
Morrison, A ;
Shaw, L .
ANAESTHESIA AND INTENSIVE CARE, 1998, 26 (04) :396-400
[3]  
Beckmann U, 1996, ANAESTH INTENS CARE, V24, P314, DOI 10.1177/0310057X9602400303
[4]   The Australian Incident Monitoring Study in intensive care: AIMS-ICU. An analysis of the first year of reporting [J].
Beckmann, U ;
Baldwin, I ;
Hart, GK ;
Runciman, WB .
ANAESTHESIA AND INTENSIVE CARE, 1996, 24 (03) :320-329
[5]   ANOTHER COMPLICATION OF ARTERIAL CANNULATION [J].
BROWN, MM .
ANAESTHESIA, 1991, 46 (04) :326-326
[6]   ARTERIAL CATHETERIZATION [J].
CLARK, VL ;
KRUSE, JA .
CRITICAL CARE CLINICS, 1992, 8 (04) :687-697
[7]  
DAMEN J, 1988, INTENS CARE MED, V14, P156
[8]  
DRAVID V, 1999, APPL RADIOL, V28, P22
[9]   ARTERIAL-OCCLUSION AFTER CANNULATION [J].
EVANS, PJD ;
KERR, JH .
BRITISH MEDICAL JOURNAL, 1975, 3 (5977) :197-199
[10]  
Franklin C, 1995, J Crit Illn, V10, P424