Study on adsorption refrigeration cycle utilizing activated carbon fibers. Part 1. Adsorption characteristics

被引:48
作者
Hamamoto, Y
Alam, KCA
Saha, BB
Koyama, S
Akisawa, A
Kashiwagi, T
机构
[1] Kyushu Univ, Dept Mech Engn Sci, Higashi Ku, Fukuoka 8128581, Japan
[2] Tokyo Univ Agr & Technol, Koganei, Tokyo 1848588, Japan
[3] Kyushu Univ, Div Adv Device Mat, Inst Mat Chem & Engn, Kasuga, Fukuoka 8168580, Japan
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2006年 / 29卷 / 02期
关键词
adsorption system; experiment; absorber; carbon fibre; water; methanol; nitrogen;
D O I
10.1016/j.ijrefrig.2005.04.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal heat driven adsorption systems using natural refrigerants have been focused on the recent energy utilization trend. However, the drawbacks of these adsorption systerns are their poor performance in terms of system cooling capacity and coefficient of performance (COP). The objective of this paper is to improve the performance of thermally powered adsorption cooling system by selecting new adsorbent-refrigerant pair. Adsorption capacity of adsorbent-refrigerant pair depends on the thermophysical properties (pore size, pore volume and pore diameter) of adsorbent and isothermal characteristics of the pair. In this paper, the thermophysical properties of two PAN types of activated carbon fibers (FX-400 and KF-1000) are determined from the nitrogen adsorption isotherms. The standard nitrogen gas adsorption/desorption measurements on various adsorbents at liquid nitrogen of temperature 77.3 K were performed. Surface area of each adsorbent was determined by the Brunauer, Emmett and Teller (BET) plot of nitrogen adsorption data. Pore size distribution was measured by the Horvath and Kawazoe (HK) method. As of the adsorption/desorption isotherms, FX-400 shows very small hysteresis when the value of PIP, exceeds 0.4, while KF-1000 has no hysteresis in the whole range of PIP.. The adsorption capacity of FX-400 is about 30% higher than that of KF-1000. The adsorption equilibrium data of activated carbon fiber (ACF)-methanol are presented and correlated with simple equations. The adsorption equilibrium data of ACF (KF-1000)-water also presented in order to facilitate comparison with those of ACFs-methanol pair. The results will contribute significantly in designing the adsorber/desorber heat exchanger for thermally driven adsorption cooling system. (c) 2005 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 22 条
[1]  
Boelman EC, 1995, ASHRAE TRAN, V101, P358
[2]   PERFORMANCE LIMITATIONS OF ADSORPTION CYCLES FOR SOLAR COOLING [J].
CRITOPH, RE .
SOLAR ENERGY, 1988, 41 (01) :21-31
[3]   KINETICS OF PHYSICAL ADSORPTION BY CARBONACEOUS ADSORBENTS OF BIPOROUS STRUCTURE [J].
DUBININ, MM ;
ERASHKO, IT ;
KADLEC, O ;
ULIN, VI ;
VOLSHCHUK, AM ;
ZOLOTAREV, PP .
CARBON, 1975, 13 (03) :193-200
[4]   ADSORPTION IN SLIT-LIKE AND CYLINDRICAL MICROPORES IN HENRYS LAW REGION - MODEL FOR MICROPOROSITY OF CARBONS [J].
EVERETT, DH ;
POWL, JC .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1976, 72 :619-636
[5]   METHOD FOR THE CALCULATION OF EFFECTIVE PORE-SIZE DISTRIBUTION IN MOLECULAR-SIEVE CARBON [J].
HORVATH, G ;
KAWAZOE, K .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1983, 16 (06) :470-475
[6]  
ISHIZAKI N, 1992, SHINBAN KASSEITAN KI, P189
[7]   Cold energy generation characteristics of adsorption heat pump using direct heat exchange module [J].
Ito, M ;
Watanabe, F ;
Hasatani, M .
KAGAKU KOGAKU RONBUNSHU, 1996, 22 (04) :926-929
[8]  
Kashiwagi T, 2002, PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, P50
[9]  
KAWATA K, 1999, ADSORPTION HDB PROCE, P598
[10]  
NISHINO H, 1999, POROUS MAT CHARACTER, P16