Development of disposable amperometric sulfur dioxide biosensors based on screen printed electrodes

被引:42
作者
Hart, JP [1 ]
Abass, AK [1 ]
Cowell, D [1 ]
机构
[1] Univ W England, Fac Sci Appl, Dept Chem & Phys Sci, Bristol BS16 1QY, Avon, England
关键词
screen-printed; amperometric biosensor; sulfur dioxide; cytochrome c; sulfite oxidase; gas sensor;
D O I
10.1016/S0956-5663(01)00308-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The possibility of developing amperometric biosensors for the measurement of SO2 in flowing gas streams has been examined. Screen-printed carbon electrodes (SPCEs) were tailored with the enzyme sulfite oxidase and cytochrome c and the response is generated through the resulting enzymatic and electrocatalytic reactions involving SO32-, formed when SO2 gas is dissolved in the supporting electrolyte. Two methods of integrating the enzyme and cytochrome e with the SPCE were investigated. In one design (b-type biosensor), the components were mixed thoroughly with the same ink used to produce the SPCEs, then the modified ink was spread over the working electrode. In the second approach the bio-components were dissolved in the supporting electrolyte and simply deposited on top of the transducer (s-type biosensor). Both devices gave linear responses over the range 4-50 ppm but the sensitivity of the s-type was approximately twice that of the b-type biosensor. In addition, the time taken to reach 90% of the maximum response (t(90%)) was 110 s for the s-type biosensor compared with 200 s for the b-type biosensor. These studies illustrate the successful use of biosensors for the detection of sulfur dioxide at the relatively low potential of + 0.3 V versus Ag.AgCl and should provide useful alternatives for decentralised environmental studies. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 13 条
[1]   Direct electrochemistry of cytochrome c at plain and membrane modified screen-printed carbon electrodes [J].
Abass, AK ;
Hart, JP .
ELECTROCHIMICA ACTA, 2001, 46 (06) :829-836
[2]   Development of an amperometric sulfite biosensor based on sulfite oxidase with cytochrome c, as electron acceptor, and a screen-printed transducer [J].
Abass, AK ;
Hart, JP ;
Cowell, D .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) :148-153
[3]   Electrocatalytic, diffusional and analytical characteristics of a cobalt phthalocyanine modified, screen-printed, amperometric gas sensor for propanethiol [J].
Abass, AK ;
Hart, JP .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 41 (1-3) :169-175
[4]   DEVELOPMENT OF A FLOW-INJECTION ANALYSIS MEDIATED BIOSENSOR FOR SULFITE [J].
GROOM, CA ;
LUONG, JHT ;
MASSON, C .
JOURNAL OF BIOTECHNOLOGY, 1993, 27 (02) :117-127
[5]   A disposable amperometric gas sensor for sulphur-containing compounds based on a chemically modified screen printed carbon electrode coated with a hydrogel [J].
Hart, JP ;
Abass, AK .
ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) :199-206
[6]   Measurements of nitrogen dioxide and sulphur dioxide concentrations in urban and rural areas of Poland using a passive sampling method [J].
Krochmal, D ;
Kalina, A .
ENVIRONMENTAL POLLUTION, 1997, 96 (03) :401-407
[7]   STUDIES WITH A SULFITE OXIDASE-MODIFIED CARBON PASTE ELECTRODE FOR DETECTION DETERMINATION OF SULFITE ION AND SO2(G) IN CONTINUOUS-FLOW SYSTEMS [J].
NADER, PA ;
VIVES, SS ;
MOTTOLA, HA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 284 (02) :323-333
[8]   Voltammetric and amperometric studies of selected thiols and dimethyldisulfide using a screen-printed carbon electrode modified with cobalt phthalocyanine: Studies towards a gas sensor [J].
Napier, A ;
Hart, JP .
ELECTROANALYSIS, 1996, 8 (11) :1006-1013
[9]   SELECTIVE CONTINUOUS FLOW-STOPPED FLOW-CONTINUOUS FLOW DETERMINATION OF SULFITE IN WHITE WINES USING IMMOBILIZED SULFITE OXIDASE ON A ROTATING REACTOR [J].
REZENDE, MO ;
MOTTOLA, HA .
ANALYST, 1994, 119 (09) :2093-2096
[10]   An assessment of spatial and temporal variation of sulfur dioxide levels over Istanbul, Turkey [J].
Tayanç, M .