Polyetherimide-silicone:: a 10 μm ultrathin composite membrane for faster and more sensitive membrane introduction mass spectrometry analysis

被引:20
作者
Alberici, R
Sparrapan, R
Eberlin, MN
Windmöller, D
Augusti, R
机构
[1] UNICAMP, Inst Chem, BR-13083970 Campinas, SP, Brazil
[2] Univ Fed Minas Gerais, Dept Chem, BR-31270901 Belo Horizonte, MG, Brazil
来源
ANALYTICAL COMMUNICATIONS | 1999年 / 36卷 / 06期
关键词
D O I
10.1039/a902185j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polyetherimide (polyester)/silicone (PEI/S) sheet composite membrane with a 10 mu m thick cross-linked silicone layer is found to display the required mechanical properties to work efficiently as the solution/high vacuum interface in membrane introduction mass spectrometry (MIMS) analysis of volatile organic compounds (VOC) in water. Owing to much shorter response and recovery times, the PEI/S membrane allows much faster analysis and calibration procedures as compared to the 250 mu m silicone membrane usually used in MIMS, When using EI, owing to excessive water permeation, responses (signal intensity) for the PEI/S membrane are not always superior, being analyte-dependent, For the more polar VOCs, however, the PEI/S membrane shows 2-3 times greater responses, improving their relatively poor MIMS detection limits, When water-methane chemical ionization is applied, the problem of excessive water permeation is attenuated, and the PEI/S membrane displays greatly superior responses.
引用
收藏
页码:221 / 223
页数:3
相关论文
共 29 条
[1]   Kinetics and mechanism of benzene derivative degradation with Fenton's reagent in aqueous medium studied by MIMS [J].
Augusti, R ;
Dias, AO ;
Rocha, LL ;
Lago, RM .
JOURNAL OF PHYSICAL CHEMISTRY A, 1998, 102 (52) :10723-10727
[2]  
Bohatka S, 1997, RAPID COMMUN MASS SP, V11, P656, DOI 10.1002/(SICI)1097-0231(199704)11:6<656::AID-RCM835>3.0.CO
[3]  
2-W
[4]   PERMEABLE MEMBRANE MASS-SPECTROMETRIC MEASUREMENT OF AN ENZYMATIC KINETIC ISOTOPE EFFECT - ALPHA-CHYMOTRYPSIN-CATALYZED TRANS-ESTERIFICATION [J].
CALVO, KC ;
WEISENBERGER, CR ;
ANDERSON, LB ;
KLAPPER, MH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1983, 105 (23) :6935-6941
[5]  
Cisper ME, 1997, RAPID COMMUN MASS SP, V11, P1449
[6]   Characterization of a membrane interface designed for analytical scale sample introduction into a mass spectrometer [J].
Dongre, AR ;
Hayward, MJ .
ANALYTICA CHIMICA ACTA, 1996, 327 (01) :1-16
[7]  
JORGENSEN L, 1987, BIOTECHNOL LETT, V9, P71
[8]   Fast multidimensional (3D and 4D) MS(2) and MS(3) scans in a high-transmission pentaquadrupole mass spectrometer [J].
Juliano, VF ;
Gozzo, FC ;
Eberlin, MN ;
Kascheres, C ;
doLago, CL .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1328-1334
[9]   MEMBRANE INLET MASS-SPECTROMETER FOR RAPID HIGH-PRECISION DETERMINATION OF N-2, O-2, AND AR IN ENVIRONMENTAL WATER SAMPLES [J].
KANA, TM ;
DARKANGELO, C ;
HUNT, MD ;
OLDHAM, JB ;
BENNETT, GE ;
CORNWELL, JC .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4166-4170
[10]  
Kasthurikrishnan N, 1996, RAPID COMMUN MASS SP, V10, P751, DOI 10.1002/(SICI)1097-0231(199605)10:7<751::AID-RCM539>3.0.CO