Immuno-monitoring of CD8+ T cells in whole blood versus PBMC samples

被引:46
作者
Appay, V
Reynard, S
Voelter, V
Romero, P
Speiser, DE
Leyvraz, S
机构
[1] CHUV, Multidisciplinary Oncol Ctr, Immunol Grp, Lausanne, Switzerland
[2] CHUV, Lausanne Branch, Ludwig Inst Canc Res, Div Clin Oncoimmunol, Lausanne, Switzerland
关键词
lymphocytes; Naive; tetramers; flow cytometry;
D O I
10.1016/j.jim.2005.11.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The study of natural T cell responses against pathogens or tumors, as well as the assessment of new immunotherapy strategies aimed at boosting these responses, requires increasingly precise ex vivo analysis of blood samples. For practical reasons, studies are often performed using purified PBMC samples, usually cryopreserved, Here, we report on FACS analyses of peripheral blood T cells, performed by direct antibody staining of non-purified total blood. For comparison, fresh PBMC, purified by Ficoll, were analysed. Our results show that the latter method can induce a bias in subpopulation distribution, in particular of CD8+ T cells, and sometimes lead to inaccurate measurement of antigen specific CD8+ T cell responses. Direct analysis of total blood can be applied to longitudinal immuno-monitoring of T cell-based therapy. While the need to purify and cryopreserve PBMC for subsequent studies is obvious, the use of whole blood has the advantage of providing unbiased results and only small amounts of blood are used. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:192 / 199
页数:8
相关论文
共 14 条
[1]   Phenotypic analysis of antigen-specific T lymphocytes [J].
Altman, JD ;
Moss, PAH ;
Goulder, PJR ;
Barouch, DH ;
McHeyzerWilliams, MG ;
Bell, JI ;
McMichael, AJ ;
Davis, MM .
SCIENCE, 1996, 274 (5284) :94-96
[2]   The assessment of antigen-specific CD8+T cells through the combination of MHC class I tetramer and intracellular staining [J].
Appay, V ;
Rowland-Jones, SL .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 268 (01) :9-19
[3]   Lessons from the study of T-cell differentiation in persistent human virus infection [J].
Appay, V ;
Rowland-Jones, SL .
SEMINARS IN IMMUNOLOGY, 2004, 16 (03) :205-212
[4]   LYMPHOCYTE SUBSET ANALYSIS BY FLOW-CYTOMETRY - COMPARISON OF 3 DIFFERENT STAINING TECHNIQUES AND EFFECTS OF BLOOD-STORAGE [J].
ASHMORE, LM ;
SHOPP, GM ;
EDWARDS, BS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 118 (02) :209-215
[5]   Optimized lymphocyte isolation methods for analysis of chemokine receptor expression [J].
Berhanu, D ;
Mortari, F ;
De Rosa, SC ;
Roederer, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 279 (1-2) :199-207
[6]   ENUMERATION OF HUMAN-LYMPHOCYTE SUBSETS BY MONOCLONAL-ANTIBODIES AND FLOW-CYTOMETRY - A COMPARATIVE-STUDY USING WHOLE-BLOOD OR MONONUCLEAR-CELLS SEPARATED BY DENSITY GRADIENT CENTRIFUGATION [J].
DEPAOLI, P ;
REITANO, M ;
BATTISTIN, S ;
CASTIGLIA, C ;
SANTINI, G .
JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 72 (02) :349-353
[7]   HIV-specific cytotoxic T cells from long-term survivors select a unique T cell receptor [J].
Dong, T ;
Stewart-Jones, G ;
Chen, N ;
Easterbrook, P ;
Xu, XN ;
Papagno, L ;
Appay, V ;
Weekes, M ;
Conlon, C ;
Spina, C ;
Little, S ;
Screaton, G ;
van der Merwe, A ;
Richman, DD ;
McMichael, AJ ;
Jones, EY ;
Rowland-Jones, SL .
JOURNAL OF EXPERIMENTAL MEDICINE, 2004, 200 (12) :1547-1557
[8]   ANALYSIS OF T-CELL SUBSETS IN NORMAL ADULTS - COMPARISON OF WHOLE-BLOOD LYSIS TECHNIQUE TO FICOLL-HYPAQUE SEPARATION BY FLOW-CYTOMETRY [J].
RENZI, P ;
GINNS, LC .
JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 98 (01) :53-56
[9]  
ROMEU MA, 1992, J IMMUNOL METHODS, V154, P7
[10]   Two subsets of memory T lymphocytes with distinct homing potentials and effector functions [J].
Sallusto, F ;
Lenig, D ;
Förster, R ;
Lipp, M ;
Lanzavecchia, A .
NATURE, 1999, 401 (6754) :708-712