Free convection from a window glazing with a venetian blind: Numerical model development

被引:12
作者
Phillips, J [1 ]
Naylor, D [1 ]
Harrison, SJ [1 ]
Oosthuizen, PH [1 ]
机构
[1] Ryerson Polytech Univ, Dept Mech Engn, Toronto, ON M5B 2K3, Canada
关键词
D O I
10.1139/tcsme-1999-0011
中图分类号
TH [机械、仪表工业];
学科分类号
0802 [机械工程];
摘要
The present numerical study examines the influence of horizontal louvres (Venetian blinds) on the convective heat transfer from a vertical isothermal surface. A steady, laminar, two dimensional, conjugate conduction/convection solution to this problem has been obtained using the finite element method. Detailed comparisons are made with temperature field and local Nusselt number data obtained using a Mach-Zehnder Interferometer. Also, numerically predicted stream function contours are compared to streamlines obtained from flow visualization experiments. All results are obtained for Pr = 0.7, as the intended application of this study is for air. Results show that as the blind tip-to-plate spacing decreases, the difference between numerical solutions and experimental results increase. This suggests that radiation heat transfer may be a significant factor at smaller blind spacings.
引用
收藏
页码:159 / 172
页数:14
相关论文
共 12 条
[1]
[Anonymous], WINDOW INNOVATIONS 9
[2]
[Anonymous], 1953, ANAL LAMINAR FREE CO
[3]
CURCIJA D, 1991, ASHRAE T, P274
[4]
DEBOER P, 1998, THESIS RYERSON POLYT
[5]
Finlayson E.U., 1993, WINDOW 4 0 DOCUMENTA
[6]
*FLUID DYN INT, 1989, FIDAP THEOR MAN US M
[7]
Experimental study of free convection at an indoor glazing surface with a Venetian blind [J].
Machin, AD ;
Naylor, D ;
Harrison, SJ ;
Oosthuizen, PH .
HVAC&R RESEARCH, 1998, 4 (02) :153-166
[8]
MACHIN AD, 1996, THESIS U W ONTARIO L
[9]
RHEAULT S, 1990, J SOLAR ENERGY ENG, V11, P89
[10]
Siegel R, 1992, THERMAL RAD HEAT TRA, P263