Improved peak detection and quantification of mass spectrometry data acquired from surface-enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform

被引:213
作者
Coombes, KR
Tsavachidis, S
Morris, JS
Baggerly, KA
Hung, MC
Kuerer, HM
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Biostat & Appl Math, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Mol & Cellular Oncol, Houston, TX 77030 USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Surg Oncol, Houston, TX 77030 USA
关键词
denoising; mass spectrometry; peak detection; peak quantification; SELDI; wavelets;
D O I
10.1002/pmic.200401261
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mass spectrometry is being used to find disease-related patterns in mixtures of proteins derived from biological fluids. Questions have been raised about the reproducibility and reliability of peak quantifications using this technology. We collected nipple aspirate fluid from breast cancer patients and healthy women, pooled them into a quality control sample, and produced 24 replicate SELDI spectra. We developed a novel algorithm to process the spectra, denoising with the undecimated discrete wavelet transform (UDWT), and evaluated it for consistency and reproducibility. UDWT efficiently decomposes spectra into noise and signal. The noise is consistent and uncorrelated. Baseline correction produces isolated peak clusters separated by flat regions. Our method reproducibly detects more peaks than the method implemented in Ciphergen software. After normalization and log transformation, the mean coefficient of variation of peak heights is 10.6%. our method to process spectra provides improvements over existing methods. Denoising using the UDWT appears to be an important step toward obtaining results that are more accurate. It improves the reproducibility of quantifications and supplies tools for investigation of the variations in the technology more carefully. Further study will be required, because we do not have a gold standard providing an objective assessment of which peaks are present in the samples.
引用
收藏
页码:4107 / 4117
页数:11
相关论文
共 31 条
[1]  
Adam BL, 2002, CANCER RES, V62, P3609
[2]   Comprehensive proteomic analysis of breast cancer cell membranes reveals unique proteins with potential roles in clinical cancer [J].
Adam, PJ ;
Boyd, R ;
Tyson, KL ;
Fletcher, GC ;
Stamps, A ;
Hudson, L ;
Poyser, HR ;
Redpath, N ;
Griffiths, M ;
Steers, G ;
Harris, AL ;
Patel, S ;
Berry, J ;
Loader, JA ;
Townsend, RR ;
Daviet, L ;
Legrain, P ;
Parekh, R ;
Terrett, JA .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2003, 278 (08) :6482-6489
[3]   A comprehensive approach to the analysis of matrix-assisted laser desorption/ionization-time of flight proteomics spectra from serum samples [J].
Baggerly, KA ;
Morris, JS ;
Wang, J ;
Gold, D ;
Xiao, LC ;
Coombes, KR .
PROTEOMICS, 2003, 3 (09) :1667-1672
[4]   Reproducibility of SELDI-TOF protein patterns in serum: comparing datasets from different experiments [J].
Baggerly, KA ;
Morris, JS ;
Coombes, KR .
BIOINFORMATICS, 2004, 20 (05) :777-U710
[5]   Noise reduction for magnetic resonance images via adaptive multiscale products thresholding [J].
Bao, P ;
Zhang, L .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (09) :1089-1099
[6]  
CHAO FT, 2000, WAVELETS CHEM, P205
[7]  
COIFMAN R. R., 1995, Wavelets and statistics, P125, DOI DOI 10.1007/978-1-4612-2544-7_9
[8]   Quality control and peak finding for proteomics data collected from nipple aspirate fluid by surface-enhanced laser desorption and ionization [J].
Coombes, KR ;
Fritsche, HA ;
Clarke, C ;
Chen, JN ;
Baggerly, KA ;
Morris, JS ;
Xiao, LC ;
Hung, MC ;
Kuerer, HM .
CLINICAL CHEMISTRY, 2003, 49 (10) :1615-1623
[9]   Analysis of raw microneurographic recordings based on wavelet de-noising technique and classification algorithm: Wavelet analysis in microneurography [J].
Diedrich, A ;
Charoensuk, W ;
Brychta, RJ ;
Ertl, AC ;
Shiavi, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (01) :41-50
[10]  
Fung ET, 2002, BIOTECHNIQUES, P34