Alleviating liver failure conditions using an integrated hybrid cryogel based cellular bioreactor as a bioartificial liver support

被引:17
作者
Damania, Apeksha [1 ]
Hassan, Mohsin [2 ]
Shirakigawa, Nana [3 ]
Mizumoto, Hiroshi [3 ]
Kumar, Anupam [2 ]
Sarin, Shiv K. [2 ]
Ijima, Hiroyuki [3 ]
Kamihira, Masamichi [3 ]
Kumar, Ashok [1 ]
机构
[1] Indian Inst Technol, Dept Biol Sci & Bioengn, Kanpur 208016, Uttar Pradesh, India
[2] Inst Liver & Biliary Sci, New Delhi, India
[3] Kyushu Univ, Dept Chem Engn, Fac Engn, Fukuoka 8190395, Japan
关键词
ADSORBENT RECIRCULATING SYSTEM; ALBUMIN DIALYSIS; CYTOTOXICITY; ISCHEMIA; PLASMA; RAT;
D O I
10.1038/srep40323
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
Conventionally, some bioartificial liver devices are used with separate plasmapheresis unit to separate out plasma from whole blood and adsorbent column to detoxify plasma before it passes through a hepatocytes-laden bioreactor. We aim to develop a hybrid bioreactor that integrates the separate modules in one compact design improving the efficacy of the cryogel based bioreactor as a bioartificial liver support. A plasma separation membrane and an activated carbon cloth are placed over a HepG2-loaded cryogel scaffold in a three-chambered bioreactor design. This bioreactor is consequently connected extracorporeally to a rat model of acute liver failure for 3 h and major biochemical parameters studied. Bilirubin and aspartate transaminase showed a percentage decrease of 20-60% in the integrated bioreactor as opposed to 5-15% in the conventional setup. Urea and ammonia levels which showed negligible change in the conventional setup increase (40%) and decrease (18%), respectively in the integrated system. Also, an overall increase of 5% in human albumin in rat plasma indicated bioreactor functionality in terms of synthetic functions. These results were corroborated by offline evaluation of patient plasma. Hence, integrating the plasmapheresis and adsorbent units with the bioreactor module in one compact design improves the efficacy of the bioartificial liver device.
引用
收藏
页数:11
相关论文
共 38 条
[1]
Advances in bioartificial liver devices [J].
Allen, JW ;
Hassanein, T ;
Bhatia, SN .
HEPATOLOGY, 2001, 34 (03) :447-455
[2]
Extracorporeal support for patients with acute and acute on chronic liver failure [J].
Aron, Jonathan ;
Agarwal, Banwari ;
Davenport, Andrew .
EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (04) :367-380
[3]
Sorbent suspensions vs. sorbent columns for extracorporeal detoxification in hepatic failure [J].
Ash, SR ;
Sullivan, TA ;
Carr, DJ .
THERAPEUTIC APHERESIS AND DIALYSIS, 2006, 10 (02) :145-153
[4]
Extracorporeal albumin dialysis with the molecular adsorbent recirculating system in acute-on-chronic liver failure: The RELIEF trial [J].
Banares, Rafael ;
Nevens, Frederik ;
Larsen, Fin Stolze ;
Jalan, Rajiv ;
Albillos, Agustin ;
Dollinger, Matthias ;
Saliba, Faouzi ;
Sauerbruch, Tilman ;
Klammt, Sebastian ;
Ockenga, Johann ;
Pares, Albert ;
Wendon, Julia ;
Bruennler, Tanja ;
Kramer, Ludwig ;
Mathurin, Philippe ;
de la Mata, Manuel ;
Gasbarrini, Antonio ;
Muellhaupt, Beat ;
Wilmer, Alexander ;
Laleman, Wim ;
Eefsen, Martin ;
Sen, Sambit ;
Zipprich, Alexander ;
Tenorio, Teresa ;
Pavesi, Marco ;
Schmidt, Hartmut H. -J. ;
Mitzner, Steffen ;
Williams, Roger ;
Arroyo, Vicente .
HEPATOLOGY, 2013, 57 (03) :1153-1162
[5]
Acute-on-chronic liver failure [J].
Bernal, William ;
Jalan, Rajiv ;
Quaglia, Alberto ;
Simpson, Kenneth ;
Wendon, Julia ;
Burroughs, Andrew .
LANCET, 2015, 386 (10003) :1576-1587
[6]
Acute liver failure [J].
Bernal, William ;
Auzinger, Georg ;
Dhawan, Anil ;
Wendon, Julia .
LANCET, 2010, 376 (9736) :190-201
[7]
Artificial and bioartificial liver devices: present and future [J].
Carpentier, B. ;
Gautier, A. ;
Legallais, C. .
GUT, 2009, 58 (12) :1690-1702
[8]
Prospective, randomized, multicenter, controlled trial of a bioartificial liver in treating acute liver failure [J].
Demetriou, AA ;
Brown, RS ;
Busuttil, RW ;
Fair, J ;
McGuire, BM ;
Rosenthal, P ;
Esch, JSA ;
Lerut, J ;
Nyberg, SL ;
Salizzoni, M ;
Fagan, EA ;
de Hemptinne, B ;
Broelsch, CE ;
Muraca, M ;
Salmeron, JM ;
Rabkin, JM ;
Metselaar, HJ ;
Pratt, D ;
De La Mata, M ;
McChesney, LP ;
Everson, GT ;
Lavin, PT ;
Stevens, AC ;
Pitkin, Z ;
Solomon, BA .
ANNALS OF SURGERY, 2004, 239 (05) :660-667
[9]
Vascular occlusion to decrease blood loss during hepatic resection [J].
Dixon, E ;
Vollmer, CM ;
Bathe, OF ;
Sutherland, F .
AMERICAN JOURNAL OF SURGERY, 2005, 190 (01) :75-86
[10]
Off-line bioartificial liver: A novel concept of treatment and its potency of liver regeneration [J].
Enosawa, S ;
Miyashita, T ;
Endo, M ;
Suzuki, S ;
Amemiya, H ;
Matsumura, T .
TRANSPLANTATION PROCEEDINGS, 2002, 34 (07) :2711-2713