MRI of the pelvis at 3 T:: very high spatial resolution with sensitivity encoding and flip-angle sweep technique in clinically acceptable scan time

被引:32
作者
Morakkabati-Spitz, N
Gieseke, J
Kuhl, C
Lutterbey, G
von Falkenhausen, M
Träber, F
Park-Simon, TW
Zivanovic, O
Schild, HH
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
[2] Philips Med Syst, Best, Netherlands
[3] Univ Bonn, Dept Gynecol & Obstet, D-53105 Bonn, Germany
关键词
high-field magnetic resonance imaging; spatial resolution; parallel imaging; variable refocusing angle; specific absorption rate reduction;
D O I
10.1007/s00330-005-0016-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The higher signal at 3.0-T allows spatial resolution to be increased without loss in image quality. We evaluated a T2-weighted turbo spin-echo sequence with high spatial resolution (3T-HR) to determine whether this provides clinically useful pelvic MRI. We designed a sequence with high spatial resolution (3T-HR) (0.45x0.46x4 mm) that was combined with parallel imaging and the variable refocusing angle technique (8.06 min). We examined 23 patients with gynecological disorders using 3T-HR and a standard sequence (3T-SP; 4.03 min; equivalent to 1.5 T). Two radiologists analyzed tissue contrast, signal to noise, detail delineation and artifact level. Tissue contrasts and signal to noise were rated equal. Motion artifacts occurred more often with 3T-SP despite the longer scanning time of 3T-HR. The higher spatial resolution provided additional information in four patients. In two patients small myomas were detected, in one patient a lymph node metastasis was apparent, and in one patient 3T-HR excluded tumor invasion. High spatial resolution pelvic studies with high image quality can be obtained at 3 T in acceptable scan time. The higher spatial resolution that is feasible at 3 T also provides more clinically relevant information.
引用
收藏
页码:634 / 641
页数:8
相关论文
共 32 条
[1]   Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries [J].
Al-Kwifi, O ;
Emery, DJ ;
Wilman, AH .
MAGNETIC RESONANCE IMAGING, 2002, 20 (02) :181-187
[2]   High-resolution diffusivity Imaging at 3.0 T for the detection of degenerative changes - A trypsin-based arthritis model [J].
Berg, A ;
Singer, T ;
Moser, E .
INVESTIGATIVE RADIOLOGY, 2003, 38 (07) :460-466
[3]   3 Tesla magnetic resonance Imaging of the prostate with combined pelvic phased-array and endorectal coils: Initial experience [J].
Bloch, BN ;
Rofsky, NM ;
Baroni, RH ;
Marquis, RP ;
Pedrosa, I ;
Lenkinski, RE .
ACADEMIC RADIOLOGY, 2004, 11 (08) :863-867
[4]  
Chen W, 1999, Top Magn Reson Imaging, V10, P63, DOI 10.1097/00002142-199902000-00006
[5]  
FEMLEE JP, 2000, ANAL RF HEATING 3 0, P2002
[6]   1H magnetic resonance spectroscopy (MRS) of the liver and hepatic malignant tumors at 3.0 Tesla [J].
Fischbach, F ;
Thormann, M ;
Ricke, J .
RADIOLOGE, 2004, 44 (12) :1192-1196
[7]  
Fütterer JJ, 2004, INVEST RADIOL, V39, P671
[8]  
GIESEKE J, 2004, P INT SOC MAG RES ME, V11, P74
[9]  
GIESEKE J, 2004, FORTSCHR ROENTG S222, V176
[10]  
Gieseke J, 2004, NEURORADIOLOGY, V46, P122