Electrochemical DNA biosensor for the detection of TT and Hepatitis B virus from PCR amplified real samples by using methylene blue

被引:141
作者
Meric, B
Kerman, K
Ozkan, D
Kara, P
Erensoy, S
Akarca, US
Mascini, M
Ozsoz, M [1 ]
机构
[1] Ege Univ, Fac Pharm, Dept Analyt Chem, TR-35100 Izmir, Turkey
[2] Ege Univ, Fac Med, Dept Microbiol, TR-35100 Izmir, Turkey
[3] Ege Univ, Fac Med, Dept Gastroenterol, TR-35100 Izmir, Turkey
[4] Dept Chem, I-50019 Sesto Fiorentino, Italy
关键词
hepatitis B virus; TT virus; polymerase chain reaction; methylene blue; DNA; biosensor;
D O I
10.1016/S0039-9140(01)00650-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
DNA biosensors based on nucleic acid hybridization processes are rapidly being developed towards the goal of rapid and inexpensive diagnosis of genetic and infectious diseases. Electrochemical transducers are often being used for detecting the DNA hybridization event, due to their high sensitivity, small dimensions, low cost, and compatibility with micro fabrication technology. In this study, an electrochemical biosensor for the voltammetric detection of DNA sequences related to the Hepatitis B virus (HBV) and TT virus (TTV) from polymerase chain reaction (PCR) amplified real samples is described for the first time. The biosensor relies on the immobilization of the 21- or 24-mer single stranded oligonucleotides (probe) related to the HBV and TTV sequences and hybridization of these oliaonucleotides with their complementary sequences (target) at carbon paste electrode (CPE). The extent of hybridization between the probe and target sequences was determined by using square wave voltammetry (SA with moving average baseline correction and methylene blue (MB) as the hybridization indicator. As a result of the interaction between MB and the bound guanine bases of hybrid at CPE surface, the MB signal decreased, when it was compared with the MB signal, which was observed with probe modified CPE. The difference between the MB signals, obtained from the hybrid modified and the probe modified CPE is used to detect the DNA sequences of the infectious diseases from PCR amplified real samples. Numerous factors affecting the target hybridization and indicator binding reactions are optimized to maximize the sensitivity. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:837 / 846
页数:10
相关论文
共 40 条
[1]  
AKARCA US, 1994, HEPATOLOGY, V19, P1366
[2]   Hybridization assay at a disposable electrochemical biosensor for the attomole detection of amplified human cytomegalovirus DNA [J].
Azek, F ;
Grossiord, C ;
Joannes, M ;
Limoges, B ;
Brossier, P .
ANALYTICAL BIOCHEMISTRY, 2000, 284 (01) :107-113
[3]  
BAIRD PA, 1988, AM J HUM GENET, V42, P677
[4]   Novel hybridization indicator methylene blue for the electrochemical detection of short DNA sequences related to the hepatitis B virus [J].
Erdem, A ;
Kerman, K ;
Meric, B ;
Akarca, US ;
Ozsoz, M .
ANALYTICA CHIMICA ACTA, 2000, 422 (02) :139-149
[5]  
Erdem A, 1999, ELECTROANAL, V11, P1372, DOI 10.1002/(SICI)1521-4109(199912)11:18<1372::AID-ELAN1372>3.0.CO
[6]  
2-4
[7]  
Erdem A, 2001, ELECTROANAL, V13, P219, DOI 10.1002/1521-4109(200103)13:3<219::AID-ELAN219>3.3.CO
[8]  
2-Z
[9]  
ERENSOY S, 2000, NATL MOL IDENTIFICAT, P34
[10]  
Erensoy Selda, 1999, Journal of Microbiological Methods, V38, P232