An adaptive controller in stationary reference frame for D-Statcom in unbalanced operation

被引:80
作者
Escobar, G [1 ]
Stankovic, AM
Mattavelli, P
机构
[1] Res Inst Sci & Technol San Luis Potosi, Dept Appl Math, IPICYT, San Luis Potosi 78216, Mexico
[2] Northeastern Univ, Dept Elect & Comp Engn, Boston, MA 02115 USA
[3] Univ Udine, Dept Elect Mech & Management Engn, DIEGM, I-33100 Udine, Italy
关键词
active filters; adaptive control; dissipative systems; nonlinear systems; reactive power control;
D O I
10.1109/TIE.2004.825270
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a passivity-based controller for a Distribution Static synchronous Compensator (D-Statcom) aimed at compensating reactive power and unbalanced harmonics in the general case of distorted and unbalanced source voltages and load currents. The proposed approach is based on the measurements of line currents, and ensures precise compensation for selected harmonics. Moreover, in order to compensate for the unavoidable uncertainty in certain system parameters, adaptation is added to the passivity-based controller. One of the major advantages of the proposed solution compared to conventional alternatives is that we are able to perform precise tracking (including higher order harmonics) even in the presence of a relatively low switching frequency, i.e., in the presence of an inverter with limited bandwidth. Simulation and experimental results are provided to illustrate the merits of our solution.
引用
收藏
页码:401 / 409
页数:9
相关论文
共 19 条
[1]   CONTROL STRATEGY OF ACTIVE POWER FILTERS USING MULTIPLE VOLTAGE-SOURCE PWM CONVERTERS [J].
AKAGI, H ;
NABAE, A ;
ATOH, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1986, 22 (03) :460-465
[2]   A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line [J].
Akagi, H ;
Fujita, H ;
Wada, K .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (03) :638-645
[3]   A new mathematical model and control of a three-phase AC-DC voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (01) :116-123
[4]   Control of square-wave inverters in high-power hybrid active filter systems [J].
Cheng, PT ;
Bhattacharya, S ;
Divan, DM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (03) :458-472
[5]  
Fang Zheng Peng, 1998, IEEE Industry Applications Magazine, V4, P21, DOI 10.1109/2943.715502
[6]  
Fukuda S, 2001, IEEE T IND APPL, V37, P888, DOI 10.1109/28.924772
[7]   THE UNIFIED POWER-FLOW CONTROLLER - A NEW APPROACH TO POWER TRANSMISSION CONTROL [J].
GYUGYI, L ;
SCHAUDER, CD ;
WILLIAMS, SL ;
RIETMAN, TR ;
TORGERSON, DR ;
EDRIS, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) :1085-1097
[8]   Statcom controls for operation with unbalanced voltages [J].
Hochgraf, C ;
Lasseter, RH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (02) :538-544
[9]  
*IEEE PES WORK GRO, 1996, FACTA APPL
[10]  
Khalil HK., 1992, NONLINEAR SYSTEMS