Novel Three-Dimensional MALDI Plate for Interfacing High-Capacity LC Separations with MALDI-TOF

被引:9
作者
Hattan, Stephen J. [1 ]
Vestal, Marvin L. [1 ]
机构
[1] Virgin Instruments Corp, Sudbury, MA 01776 USA
关键词
D O I
10.1021/ac8017108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) sample plates employing collimated-hole structures have been developed that allow capture and concentration of samples while simultaneously acting as a sink for carrier solvents. These plates were designed to provide an efficient interface between higher-capacity liquid chromatography (LC) separations and MALDI-TOF mass spectrometry (MS). LC-MALDI using conventional plates can accommodate the low-flow (< 1 mu L/min) separation protocols typically used in on-line LC-MS methods, and can also be used, with higher flow rate, larger columns, but are ultimately limited by the capacity of the two-dimensional surface onto which the sample is deposited. Typically, about 1 mu L of chromatographic effluent plus 1 mu L of matrix solution can be deposited and dried on a ca. 3 mm diameter spot Deposition rates (spot dwell time) are determined by the chromatographic resolution and the flow rate. To overcome this limitation, a new three-dimensional MALDI sample plate has been developed using collimated-hole structures (CHS) with monolithic chromatography media filling the holes in the collimated-hole structures. These new plates retain all of the required features of conventional sample plates, commonly formed from stainless steel, but provide additional capacity for capturing and concentrating samples. Results are presented from reversed-phase separation of peptides on a 1 mm W. column operating at flow rate of 50 mu L/min. Typically, 10 mu L of effluent can be collected on a single spot, and sample and matrix dried on a 1 mm diameter spot, to yield about 30-fold enrichment of sample concentration in matrix crystals on the surface compared to the conventional plate. Sample loadings ranging from 1 fmol to 10 pmol/spot were investigated.
引用
收藏
页码:9115 / 9123
页数:9
相关论文
共 46 条
[1]  
Ackermann BL, 2006, CURR DRUG METAB, V7, P525
[2]  
Beavis R C, 1989, Rapid Commun Mass Spectrom, V3, P233, DOI 10.1002/rcm.1290030708
[3]   System suitability in bioanalytical LC/MS/MS [J].
Briscoe, Chad J. ;
Stiles, Mark R. ;
Hage, David S. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) :484-491
[4]  
Celis JE, 2005, MOL CELL PROTEOMICS, V4, P345
[5]   LC-MS for protein characterization: current capabilities and future trends [J].
Chen, Guodong ;
Pramanik, Birendra N. .
EXPERT REVIEW OF PROTEOMICS, 2008, 5 (03) :435-444
[6]   HIGH-RESOLUTION DETECTION OF COLLISION-INDUCED DISSOCIATION FRAGMENTS BY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CODY, RB ;
FREISER, BS .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1431-1433
[7]   A MICROSCALE ELECTROSPRAY INTERFACE FOR ONLINE, CAPILLARY LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY OF COMPLEX PEPTIDE MIXTURES [J].
DAVIS, MT ;
STAHL, DC ;
HEFTA, SA ;
LEE, TD .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4549-4556
[8]   Integrated selective enrichment target -: a microtechnology platform for matrix-assisted laser desorption/ionization-mass spectrometry applied on protein biomarkers in prostate diseases [J].
Ekström, S ;
Wallman, L ;
Malm, J ;
Becker, C ;
Lilja, H ;
Laurell, T ;
Marko-Varga, G .
ELECTROPHORESIS, 2004, 25 (21-22) :3769-3777
[9]   Polymeric integrated selective enrichment target (ISET) for solid-phase-based sample preparation in MALDI-TOF MS [J].
Ekstrom, Simon ;
Wallman, Lars ;
Helldin, Goran ;
Nilsson, Johan ;
Marko-Varga, Gyorgy ;
Laurell, Thomas .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (11) :1445-1452
[10]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71