Low field (10 mT) pulsed dynamic nuclear polarization

被引:17
作者
Alecci, M [1 ]
Lurie, DJ [1 ]
机构
[1] Univ Aberdeen, Dept Biomed Phys & Bioengn, Aberdeen AB25 2ZD, Scotland
关键词
DNP; EPR; pulsed; CW; single electron contrast agents;
D O I
10.1006/jmre.1999.1721
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
EPR irradiation by a train of inverting pulses has potential advantages over continuous-wave EPR irradiation in DNP applications; however, it has previously been used only at high field (5 T), This paper presents the design and testing of an apparatus for performing pulsed DNP experiments at 10 mT with large samples (17 ml). Experimental results using pulsed DNP with an aqueous solution of a narrow-linewidth Paramagnetic probe are presented. A maximum DNP enhancement of about -36 with a train of inverting pulses (width 500 ns, repetition time 4 mu s) was measured. A preliminary comparison showed that, when the same enhancement value is considered, the pulsed DNP technique requires an average power that is about three times higher than that required with the CW irradiation. However, for in vivo DNP applications it is very important to minimize the average power deposited in the sample. From the experimental results reported in this work, when considering the maximum enhancement, the pulsed technique requires only 2% of the average power necessary with the CW DNP technique. We believe that this reduction in the average power can be important for future DNP studies with large biological-samples. (C) 1999 Academic Press.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 31 条
[1]   A submicrosecond resonator and receiver system for pulsed magnetic resonance with large samples [J].
Alecci, M ;
Brivati, JA ;
Placidi, G ;
Testa, L ;
Lurie, DJ ;
Sotgiu, A .
JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) :162-166
[2]  
ALECCI M, 1998, THESIS U ABERDEEN AB
[3]  
Andersson S., 1996, U. S. Patent, Patent No. 5530140
[4]  
ANDERSSON S, 1990, RADIOLOGY, V177, P246
[5]   EPR and DNP properties of certain novel single electron contrast agents intended for oximetric imaging [J].
Ardenkjær-Larsen, JH ;
Laursen, I ;
Leunbach, I ;
Ehnholm, G ;
Wistrand, LG ;
Petersson, JS ;
Golman, K .
JOURNAL OF MAGNETIC RESONANCE, 1998, 133 (01) :1-12
[6]  
BERTINI I, 1984, HDB ELECT SPIN RESON
[7]  
BRASCH RC, 1992, RADIOLOGY, V183, P1
[8]   POLARIZATION OF NUCLEAR SPINS IN METALS [J].
CARVER, TR ;
SLICHTER, CP .
PHYSICAL REVIEW, 1953, 92 (01) :212-213
[9]  
Golman K, 1998, ACTA RADIOL, V39, P10
[10]   INVIVO DETECTION OF INJECTED FREE-RADICALS BY OVERHAUSER EFFECT IMAGING [J].
GRUCKER, D .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :140-147