Statistical tomographic reconstruction: How many more iterations to go?

被引:9
作者
de Jonge, FAA [1 ]
Blokland, KJAK [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med, NL-2300 RC Leiden, Netherlands
关键词
iterative reconstruction; single-photon emission tomography; clinical application; quantitative measurement;
D O I
10.1007/s002590050579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Single-photon emission tomography (SPET) is a popular, commonly used method to image the three-dimensional distribution of a radiopharmaceutical within the human body. In clinical studies, filtered back-projection (FBP) still seems to be the method of choice for tomographic reconstruction, although most manufacturers of gamma cameras include iterative statistical reconstruction methods in their basic software package. Quite a lot of progress in the development of these iterative methods has been made during the past few years and promising typical clinical examples have been shown. But there is still a need for a clinical comparison of the new and the old methods in patient studies. The processing time, even on state-of-the-art computer systems, may be the most prohibitive factor for using the more advanced iterative reconstruction methods including scatter and attenuation correction.
引用
收藏
页码:1247 / 1250
页数:4
相关论文
共 18 条
[1]
Beekman FJ, 1998, J NUCL MED, V39, P1996
[2]
EXPECTATION MAXIMIZATION IN QUANTITATIVE SINGLE-PHOTON EMISSION TOMOGRAPHY [J].
BLOKLAND, KAK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (07) :595-596
[3]
SCATTER CORRECTION IN SCINTIGRAPHY - THE STATE-OF-THE-ART [J].
BUVAT, I ;
BENALI, H ;
TODDPOKROPEK, A ;
DIPAOLA, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (07) :675-694
[4]
Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormalities [J].
Gallowitsch, HJ ;
Sykora, J ;
Mikosch, P ;
Kresnik, E ;
Unterweger, O ;
Molnar, M ;
Grimm, G ;
Lind, P .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (03) :220-228
[5]
Gilland DR, 1998, J NUCL MED, V39, P1105
[6]
GORIS M, 1983, CLIN MATH INTRO COMP
[7]
Application of transmission scan-based attenuation compensation to scatter-corrected thallium-201 myocardial single-photon emission tomographic images [J].
Hashimoto, J ;
Ogawa, K ;
Kubo, A ;
Ichihara, T ;
Motomura, N ;
Takayama, T ;
Iwanaga, S ;
Mitamura, H ;
Ogawa, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (02) :120-127
[8]
Hollinger EF, 1998, J NUCL MED, V39, P1335
[9]
ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[10]