FIB Preparation and SEM Investigations for Three-Dimensional Analysis of Cell Cultures on Microneedle Arrays

被引:11
作者
Friedmann, A. [1 ,2 ]
Cismak, A. [1 ]
Tautorat, C. [3 ]
Koester, P. J. [3 ]
Baumann, W. [3 ]
Held, J. [4 ]
Gaspar, J. [4 ]
Ruther, P. [4 ]
Paul, O. [4 ]
Heilmann, A. [1 ]
机构
[1] Fraunhofer Inst Mech Mat IWM, D-06120 Halle, Saale, Germany
[2] Translat Ctr Regenerat Med TRM, Leipzig, Germany
[3] Univ Rostock, Dept Biophys, Rostock, Germany
[4] Univ Freiburg, Dept Microsyst Engn IMTEK, D-79106 Freiburg, Germany
关键词
SEM; focused ion beam; 3D reconstruction; cell culture; SCANNING-ELECTRON-MICROSCOPY; BIOLOGICAL SAMPLES;
D O I
10.1002/sca.20297
中图分类号
TH7 [仪器、仪表];
学科分类号
080401 [精密仪器及机械];
摘要
We report the investigation of the interfaces between microneedle arrays and cell cultures in patch-on-chip systems by using Focused Ion Beam (FIB) preparation and Scanning Electron Microscopy (SEM). First, FIB preparations of micro chips are made to determine the size and shape of the designed microneedles. In this essay, we investigate the cell-substrate interaction, especially the cell adhesion, and the microneedle's potential cell penetration. For this purpose, cross-sectional preparation of these hard/soft hybrid structures is performed by the FIB technology. By applying the FIB technology followed by high-resolution imaging with SEM, new insights into the cell-substrate interface can be received. One can clearly distinguish between cells that are only in contact with microneedles and cells that are penetrated by microneedles. A stack of slice images is collected by the application of the slice-and-view setup during FIB preparation and is used for threedimensional reconstruction of cells and micro-needles. SCANNING 34: 221-229, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:221 / 229
页数:9
相关论文
共 22 条
[1]
Focused ion beam milling and scanning electron microscopy characterization of polymer plus metal hybrids [J].
Brostow, Witold ;
Gorman, Brian P. ;
Olea-Mejia, Oscar .
MATERIALS LETTERS, 2007, 61 (06) :1333-1336
[2]
Brüggemann A, 2006, SMALL, V2, P840, DOI [10.1002/smll.200600083, 10.1002/50111.200600083]
[3]
Surface damage induced by FIB milling and imaging of biological samples is controllable [J].
Drobne, Damjana ;
Milani, Marziale ;
Leser, Vladka ;
Tatti, Francesco .
MICROSCOPY RESEARCH AND TECHNIQUE, 2007, 70 (10) :895-903
[4]
Investigation of cell-substrate interactions by focused ion beam preparation and scanning electron microscopy [J].
Friedmann, Andrea ;
Hoess, Andreas ;
Cismak, Andreas ;
Heilmann, Andreas .
ACTA BIOMATERIALIA, 2011, 7 (06) :2499-2507
[5]
High-aspect ratio submicrometer needles for intracellular applications [J].
Hanein, Y ;
Schabmueller, CGJ ;
Holman, G ;
Lücke, P ;
Denton, DD ;
Böhringer, KF .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (04) :S91-S95
[6]
Heilmann A, 2007, MRS P
[7]
HOLLOW MICRONEEDLE ELECTRODE ARRAYS FOR INTRACELLULAR RECORDING APPLICATIONS [J].
Held, J. ;
Gaspar, J. ;
Koester, P. J. ;
Tautorat, C. ;
Hagner, M. ;
Cismak, A. ;
Heilmann, A. ;
Baumann, W. ;
Ruther, P. ;
Paul, O. .
IEEE 22ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2009), 2009, :220-223
[8]
Design of experiment characterization of microneedle fabrication processes based on dry silicon etching [J].
Held, J. ;
Gaspar, J. ;
Ruther, P. ;
Hagner, M. ;
Cismak, A. ;
Heilmann, A. ;
Paul, O. .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (02)
[9]
Held J, 2008, PROC IEEE MICR ELECT, P268
[10]
Held J, 2010, 7 INT M SUBSTR INT M, P247