Experimental study of air entrainment mode with natural ventilation using shafts in road tunnel fires

被引:153
作者
Fan, C. G. [1 ]
Ji, J. [1 ]
Gao, Z. H. [1 ]
Han, J. Y. [1 ]
Sun, J. H. [1 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Peoples R China
基金
中国国家自然科学基金;
关键词
Road tunnel; Fire; Natural ventilation; Shaft; Air entrainment; CRITICAL VELOCITY; LAYER INTERFACE; BURNING RATE; POOL FIRE; SIMULATIONS; PERFORMANCE; RATES; FIELD;
D O I
10.1016/j.ijheatmasstransfer.2012.09.047
中图分类号
O414.1 [热力学];
学科分类号
摘要
A set of burning experiments with n-heptane pool fire were conducted to investigate the air entrainment mode with natural ventilation using shafts in road tunnel fires. One criterion was proposed to determine the critical shaft height of the plug-holing occurrence in our previous work whereas this study quantificationally analyzes the effect of plug-holing on the smoke exhaust efficiency. The disturbance of smoke exhausting on the smoke-air interface, which causes different amounts of fresh air exhausted directly and indirectly, is investigated. Results show that using vertical shafts to discharge smoke leads to a strong mixing process between the smoke layer and the fresh air. Consequently, about 2/3 of the smoke exhausting rate of the shaft is air. Moreover, some of the entrained air mixes into the smoke layer downstream the shaft, resulting, in a small reduction amount of the spilling smoke, which also proves an inefficient smoke exhausting process. Hence, for the sake of improving effectiveness of natural ventilation, some significant improvements are needed in practice. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:750 / 757
页数:8
相关论文
共 33 条
[1]   Toxicity of fire smoke [J].
Alarie, Y .
CRITICAL REVIEWS IN TOXICOLOGY, 2002, 32 (04) :259-289
[2]   Initial fuel temperature effects on burning rate of pool fire [J].
Chen, Bing ;
Lu, Shou-Xiang ;
Li, Chang-Hai ;
Kang, Quan-Sheng ;
Lecoustre, Vivien .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 188 (1-3) :369-374
[3]   Determination of the Smoke Layer Interface Height for Hot Smoke Tests in Big Halls [J].
Chow, W. K. .
JOURNAL OF FIRE SCIENCES, 2009, 27 (02) :125-142
[4]   Mass flow rates across layer interface in a two-layer zone model in an atrium with mechanical exhaust system [J].
Chow, WK ;
Yi, L ;
Shi, CL ;
Li, YZ ;
Huo, R .
BUILDING AND ENVIRONMENT, 2006, 41 (09) :1198-1202
[5]   AN EXPERIMENTAL-STUDY OF UPPER HOT LAYER STRATIFICATION IN FULL-SCALE MULTI-ROOM FIRE SCENARIOS [J].
COOPER, LY ;
HARKLEROAD, M ;
QUINTIERE, J ;
RINKINEN, W .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (04) :741-749
[6]   Fire-induced smoke control via hybrid ventilation in a huge transit terminal subway station [J].
Gao, Ran ;
Li, Angui ;
Hao, Xinpeng ;
Lei, Wenjun ;
Zhao, Yujiao ;
Deng, Baoshun .
ENERGY AND BUILDINGS, 2012, 45 :280-289
[7]   Effects of the ventilation duct arrangement and duct geometry on ventilation performance in a subway tunnel [J].
Huang Yuan-dong ;
Gong Xiao-lu ;
Peng Yue-jiao ;
Lin Xiao-yu ;
Chang-Nyung, Kim .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2011, 26 (06) :725-733
[8]   The critical ventilation velocity in tunnel fires - a computer simulation [J].
Hwang, CC ;
Edwards, JC .
FIRE SAFETY JOURNAL, 2005, 40 (03) :213-244
[9]   Heat release rates from heavy goods vehicle trailer fires in tunnels [J].
Ingason, H ;
Lönnermark, A .
FIRE SAFETY JOURNAL, 2005, 40 (07) :646-668
[10]   A study of the effect of plug-holing and boundary layer separation on natural ventilation with vertical shaft in urban road tunnel fires [J].
Ji, J. ;
Gao, Z. H. ;
Fan, C. G. ;
Zhong, W. ;
Sun, J. H. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (21-22) :6032-6041