Influence of Investment, Disinfection, and Storage on the Microhardness of Ocular Resins

被引:31
作者
Goiato, Marcelo Coelho [1 ]
dos Santos, Daniela Micheline [1 ]
Gennari-Filho, Humberto [1 ]
Zavanelli, Adriana Cristina [1 ]
de Carvalho Dekon, Stefan Fiuza [1 ]
Mancuso, Daniela Nardi [1 ]
机构
[1] UNESP Sao Paulo State Univ, Dept Dent Mat & Prosthodont, Sch Dent Aracatuba, BR-16050050 Sao Paulo, Brazil
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2009年 / 18卷 / 01期
关键词
Acrylic resins; facial prostheses; hardness;
D O I
10.1111/j.1532-849X.2008.00372.x
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Purpose: The longevity of an ocular prosthesis is directly related to the resistance to erosion of its material. The purpose of this study was to evaluate the effects of chemical disinfection and the method of investment on the microhardness of ocular prosthesis acrylic resin. Materials and Methods: Thirty-two test specimen investments were obtained in two silicones. A segment was cut in each test specimen, and each specimen was fixed in an acrylic disk. The specimens were then polished and submitted to the first microhardness test before immersion in distilled water and incubation for 2 months. During this 2-month period, the specimens were immersed in a water bath at 37 degrees C and were disinfected daily; half were disinfected with neutral soap and the other half were disinfected with 4% chlorhexidine gluconate. After the storage phase and disinfection, a second microhardness test was performed. The surface microhardness values for the acrylic resins were submitted to ANOVA, followed by the Tukey test. Results: The disinfection and the period of storage did not statistically influence the surface microhardness of the acrylic resin, independent of the method of investment of the specimens (Zetalabor or Vipi Sil). The investment of specimens with Zetalabor silicone presented a greater surface hardness, independent of the type of disinfection and the period of storage. Conclusions: Based on these results, we suggest that the microhardness of the resin evaluated was not influenced by the method of disinfection or the time of storage used and was affected only by the investment material.
引用
收藏
页码:32 / 35
页数:4
相关论文
共 17 条
[1]
ANUSAVICE KJ, 2003, PHILLIPS SCI DENT MA, P709
[2]
Asad Tehmina, 1993, International Journal of Prosthodontics, V6, P9
[3]
DIMENSIONAL STABILITY OF CONDENSATION SILICONE RUBBERS [J].
BRADEN, M .
BIOMATERIALS, 1992, 13 (05) :333-336
[4]
DIMENSIONAL STABILITY OF SILICONE-BASED IMPRESSION MATERIALS [J].
FANO, V ;
GENNARI, PU ;
ORTALLI, I .
DENTAL MATERIALS, 1992, 8 (02) :105-109
[5]
KAHN RC, 1982, J PROSTHET DENT, V47, P556, DOI 10.1016/0022-3913(82)90309-2
[6]
ELASTOMERIC IMPRESSION MATERIALS - THE MEASUREMENT OF SOME PROPERTIES RELEVANT TO CLINICAL-PRACTICE [J].
MCCABE, JF ;
STORER, R .
BRITISH DENTAL JOURNAL, 1980, 149 (03) :73-79
[7]
COMPLETE DENTURE RETENTION .2. WETTABILITY STUDIES ON VARIOUS ACRYLIC RESIN DENTURE BASE MATERIALS [J].
MONSENEGO, P ;
BASZKIN, A ;
COSTA, MD ;
LEJOYEUX, J .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (03) :308-312
[8]
Hardness of heat-polymerized acrylic resins after disinfection and long-term water immersion [J].
Neppelenbroek, KH ;
Pavarina, AC ;
Vergani, CE ;
Giampaolo, ET .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (02) :171-176
[9]
Paffenbarger G C, 1972, J Am Dent Assoc, V84, P1333
[10]
The effect of disinfectant solutions on the hardness of acrylic resin denture teeth [J].
Pavarina, AC ;
Vergani, CE ;
Machado, AL ;
Giampaolo, ET ;
Teraoka, MT .
JOURNAL OF ORAL REHABILITATION, 2003, 30 (07) :749-752