Techniques to alleviate the effects of view aliasing artifacts in computed tomography

被引:24
作者
Galigekere, RR
Wiesent, K
Holdsworth, DW
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Siemens AG, Med Engn Grp, D-91052 Erlangen, Germany
[3] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5K8, Canada
[4] Univ Western Ontario, Dept Diagnost Radiol, London, ON N6A 5K8, Canada
关键词
computed tomography; reconstruction; view aliasing artifacts;
D O I
10.1118/1.598606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Due to practical limitations in data acquisition, 3-D computed tomography systems must attempt to provide rapid reconstructions of acceptable quality from a Limited number of views. The use of convolution backprojection (CBP) for image reconstruction from an inadequate number of projections, results in view aliasing artifacts. In this paper we investigate different post-processing methods of alleviating the effects of view aliasing artifacts. Two distinct methods and their variants are considered. The first, termed the intermediate view reprojection (IVR) method, involves estimating a set of intermediate views by reprojection, followed by a reconstruction using the augmented sec of views. The second, termed the error-correction (EC) method, incorporates a correction on the initial reconstruction based on the projection-domain error. Suitable modifications and variants of the above methods are indicated. Of the methods discussed, the IVR method is simple, tends to reduce the effects of artifacts with less susceptibility to secondary effects, and is applicable to region-of-interest reconstructions. (C) 1999 American Association of Physicists in Medicine.
引用
收藏
页码:896 / 904
页数:9
相关论文
共 30 条
[2]   REPROJECTION USING A PARALLEL BACKPROJECTOR [J].
CRAWFORD, CR .
MEDICAL PHYSICS, 1986, 13 (04) :480-483
[3]  
Fahrig R, 1997, AM J NEURORADIOL, V18, P1507
[4]   Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion [J].
Fahrig, R ;
Moreau, M ;
Holdsworth, DW .
MEDICAL PHYSICS, 1997, 24 (07) :1097-1106
[5]  
FELIX DS, 1990, NATO ASI SER, V60, P147
[6]   AN ALGORITHM FOR THE REDUCTION OF METAL CLIP ARTIFACTS IN CT RECONSTRUCTIONS [J].
GLOVER, GH ;
PELC, NJ .
MEDICAL PHYSICS, 1981, 8 (06) :799-807
[7]   ALGEBRAIC RECONSTRUCTION TECHNIQUES (ART) FOR 3-DIMENSIONAL ELECTRON MICROSCOPY AND X-RAY PHOTOGRAPHY [J].
GORDON, R ;
BENDER, R ;
HERMAN, GT .
JOURNAL OF THEORETICAL BIOLOGY, 1970, 29 (03) :471-&
[8]   COMMENTS ON GEOMETRIC DECONVOLUTION - A META-ALGORITHM FOR LIMITED VIEW COMPUTED-TOMOGRAPHY - REPLY [J].
GORDON, R ;
DHAWAN, AP ;
RANGAYYAN, RM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) :242-244
[9]   GEOMETRIC DECONVOLUTION - A META-ALGORITHM FOR LIMITED VIEW COMPUTED-TOMOGRAPHY [J].
GORDON, R ;
RANGAYYAN, RM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (12) :806-810
[10]  
HEFFERNAN PB, 1983, IEEE T BIOMED ENG, V30, P383