Evidence for a relation between inspired gas mixture and the left ventricular contrast achieved with Albunex(R) in a canine model

被引:6
作者
Geiser, EA
Buss, DD
Wible, JH
Cunningham, MS
Webb, AI
Wilson, DC
Yang, M
机构
[1] UNIV WISCONSIN,SCH VET MED,MADISON,WI 53706
[2] MALLINKRODT MED INC,ST LOUIS,MO
[3] UNIV FLORIDA,COLL VET MED,DEPT PHYSIOL SCI,GAINESVILLE,FL 32610
[4] UNIV FLORIDA,COLL ARTS & SCI,DEPT STAT,GAINESVILLE,FL 32610
关键词
echocardiography; contrast agents; video densitometry; border detection; sonicated albumin; oxygen;
D O I
10.1002/clc.4960190403
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In a previous experiment, a marked reduction in the right- and left-sided contrast effect of Albunex was noted in an intubated animal spontaneously breathing isoflurane in 100% oxygen. The theory suggests that the time course of echogenicity of microbubbles in a liquid is dependent on the pressure and the gradients of dissolved gases. The present set of experiments tested whether the loss of contrast occurs at commonly used therapeutic concentrations of inspired oxygen. Hypothesis: This research tested the hypothesis that the left ventricular (LV) contrast effect achieved with intravenous injection of the ultrasound contrast agent Albunex(R) is related to the inspired oxygen content. Methods: Intubated dogs were maintained in a spontaneously respiring anesthetic state on isoflurane and mixtures of oxygen (12-50%) in nitrogen. FIO2 was held steady for 15 min prior to injection of 0.08 ml/kg of Albunex. The contrast effects were recorded from a transthoracic short-axis view. Left and right ventricular brightness curves were generated from digitized sequences of end-diastolic frames. The minimum and maximum brightness and area under the time brightness curves were determined. Results: The LV maximum brightness and area under the curve showed significant negative correlations (p = < 0.004) with the FIO2, while the minimum brightness showed a significant positive correlation (p = < 0.002). No significant correlations were found for the right ventricular brightness parameters. Conclusions: These findings show an important relationship between the FIO2 and loss of the contrast effect of Albunex. This loss occurs at oxygen concentrations in the therapeutic range, but could be overcome by increasing the dose of Albunex. The mechanism is likely related to an outward nitrogen gradient causing a loss of echogenicity. The clinical implication is that patients on supplemental oxygen may require higher doses of Albunex to achieve optimal opacification.
引用
收藏
页码:289 / 295
页数:7
相关论文
共 22 条
[1]  
CHEIRIF-B J, 1992, Journal of the American College of Cardiology, V19, P1343
[2]   OPACIFICATION AND BORDER DELINEATION IMPROVEMENT IN PATIENTS WITH SUBOPTIMAL ENDOCARDIAL BORDER DEFINITION IN ROUTINE ECHOCARDIOGRAPHY - RESULTS OF THE PHASE-III ALBUNEX MULTICENTER TRIAL [J].
CROUSE, LJ ;
CHEIRIF, J ;
HANLY, DE ;
KISSLO, JA ;
LABOVITZ, AJ ;
RAICHLEN, JS ;
SCHUTZ, RW ;
SHAH, PM ;
SMITH, MD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1494-1500
[3]   SONICATED SERUM-ALBUMIN IN CONTRAST ECHOCARDIOGRAPHY - IMPROVED SEGMENTAL WALL MOTION DEPICTION AND IMPLICATIONS FOR STRESS ECHOCARDIOGRAPHY [J].
CROUSE, LJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (20) :H42-H45
[4]  
CROUSE LJ, 1991, CLIN CARDIOL S5, V14, P19
[5]  
DEJONG N, 1993, ULTRASOUND MED BIOL, V19, P279, DOI 10.1016/0301-5629(93)90100-3
[6]   ASSESSMENT OF REGIONAL MYOCARDIAL PERFUSION WITH MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY IN A CANINE MODEL OF VARYING DEGREES OF CORONARY STENOSIS [J].
DESIR, RM ;
CHEIRIF, J ;
BOLLI, R ;
ZOGHBI, WA ;
HOYT, BD ;
QUINONES, MA .
AMERICAN HEART JOURNAL, 1994, 127 (01) :56-63
[7]   ON THE STABILITY OF GAS BUBBLES IN LIQUID-GAS SOLUTIONS [J].
EPSTEIN, PS ;
PLESSET, MS .
JOURNAL OF CHEMICAL PHYSICS, 1950, 18 (11) :1505-1509
[8]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ULTRASOUND CONTRAST AGENT - INITIAL MULTICENTER CLINICAL-RESULTS [J].
FEINSTEIN, SB ;
CHEIRIF, J ;
TENCATE, FJ ;
SILVERMAN, PR ;
HEIDENREICH, PA ;
DICK, C ;
DESIR, RM ;
ARMSTRONG, WF ;
QUINONES, MA ;
SHAH, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) :316-324
[9]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ECHO CONTRAST AGENT IN ECHOCARDIOGRAPHIC STUDIES IN PATIENTS [J].
GENY, B ;
METTAUER, B ;
MUAN, B ;
BISCHOFF, P ;
EPAILLY, E ;
PIQUARD, F ;
EISENMANN, B ;
HABEREY, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1193-1198
[10]  
Keller M W, 1989, J Am Soc Echocardiogr, V2, P48