Comparison of efficacy and cost-effectiveness of BIOMIC VIDEO and vitek antimicrobial susceptibility test systems for use in the clinical microbiology laboratory

被引:21
作者
Berke, I [1 ]
Tierno, PM [1 ]
机构
[1] NYU, MED CTR, TISCH HOSP, DEPT PATHOL & MICROBIOL, NEW YORK, NY 10016 USA
关键词
D O I
10.1128/JCM.34.8.1980-1984.1996
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Antimicrobial susceptibility testing expense mag be a significant portion of a clinical microbiology laboratory's budget. This study compares the BIOMIC VIDEO system (Giles Scientific, Inc., New York, N.Y.) with the Vitek system (bioMerieux Vitek, Inc., Hazelwood Mo.), an established automated method of antimicrobial susceptibility testing with the ability to generate MIC data. The BIOMIC system is relatively inexpensive and automates the reading of the classical disk agar diffusion test to provide both qualitative (susceptibility interpretation) and quantitative (MIG) data. The overall MIC correlation between the two systems for the 2,913 drug-organism combinations tested was 92.6%. The overall agreement for susceptibility interpretationm was 97.4%. The BIOMIC system offers a 57.4% savings per test over the Vitek system. The BIOMIC system utilizes an older technology which is more efficient and yet yields results comparable to those of established automated MIC methods. The savings achievable in laboratories and hospitals nationwide may contribute significantly to the containment of national health care expenditures.
引用
收藏
页码:1980 / 1984
页数:5
相关论文
共 13 条
[1]   RAPID ANTIMICROBIAL SUSCEPTIBILITY TESTING OF GRAM-NEGATIVE CLINICAL ISOLATES WITH THE AUTOMICROBIC SYSTEM [J].
BACKES, BA ;
CAVALIERI, SJ ;
RUDRIK, JT ;
BRITT, EM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 19 (06) :744-747
[2]   PIPERACILLIN SUSCEPTIBILITY TESTS BY THE SINGLE-DISK AGAR DIFFUSION TECHNIQUE [J].
BARRY, AL ;
THORNSBERRY, C ;
BADAL, RE ;
BAKER, CN ;
JONES, RN ;
GERLACH, EH .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1979, 16 (03) :378-385
[3]  
BARRY AL, 1976, ANTIMICROBIC SUSCEPT, P196
[4]  
BAUER AW, 1966, AM J CLIN PATHOL, V45, P493
[5]   EVALUATION OF THE BIOGRAM ANTIMICROBIAL SUSCEPTIBILITY TEST SYSTEM [J].
DAMATO, RF ;
HOCHSTEIN, L ;
VERNALEO, JR ;
CLERI, DJ ;
WALLMAN, AA ;
GRADUS, MS ;
THORNSBERRY, C .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (05) :793-798
[6]  
ERICSSON HM, 1971, ACTA PATHOLOG MICROB, P1
[7]   CONCURRENT COMPARABILITY OF AUTOMATED SYSTEMS AND COMMERCIALLY PREPARED MICRODILUTION TRAYS FOR SUSCEPTIBILITY TESTING [J].
HANSEN, SL ;
FREEDY, PK .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 17 (05) :878-886
[8]  
*NAT COMM CLIN LAB, 1994, M11A3 NAT COMM CLIN
[9]  
*NAT COMM CLIN LAB, 1994, M2A5 NAT COMM CLIN L
[10]  
*NAT COMM CLIN LAB, 1994, M7A3 NAT COMM CLIN L