Multi-society guideline for reprocessing flexible gastrointestinal endoscopes

被引:20
作者
Nelson, DB [1 ]
Jarvis, WR
Rutala, WA
Foxx-Orenstein, AE
Isenberg, G
Dash, GP
Alvarado, CJ
Ball, M
Griffin-Sobel, J
Petersen, C
Ball, KA
Henderson, J
Stricof, RL
机构
[1] Amer Soc Gastrointestinal Endoscopy, Oak Brook, IL 60523 USA
[2] Soc Healthcare Epidemiol Amer, Mt Royal, NJ 08061 USA
[3] Univ N Carolina Hlth Care Syst, Chapel Hill, NC USA
[4] Amer Coll Gastroenterol, Arlington, VA 22206 USA
[5] Assoc Profess Infect Control & Epidemiol, Washington, DC 20005 USA
[6] Soc Gastroenterol Nurses & Associates Inc, Chicago, IL 60611 USA
[7] Assoc Perioperat Registered Nurses, Denver, CO 80231 USA
[8] New York State Dept Hlth, Albany, NY 12237 USA
关键词
D O I
10.1007/s10350-003-0098-2
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Flexible gastrointestinal endoscopy is a valuable diagnostic and therapeutic tool for the care of patients with gastrointestinal and pancreaticobiliary disorders. Compliance with accepted guidelines for the reprocessing of gastrointestinal endoscopes between patients is critical to the safety and success of their use. When these guidelines are followed, pathogen transmission can be effectively prevented. Increased efforts and resources should be directed to improve compliance with these guidelines. Further research in the area of gastrointestinal endoscope reprocessing should be encouraged. The organizations that endorsed this guideline are committed to assisting the FDA and manufacturers in addressing critical infection control issues in gastrointestinal device reprocessing.
引用
收藏
页码:413 / 420
页数:8
相关论文
共 79 条
[1]   IN-HOSPITAL EVALUATION OF CONTAMINATION OF DUODENOSCOPES - A QUANTITATIVE ASSESSMENT OF THE EFFECT OF DRYING [J].
ALFA, MJ ;
SITTER, DL .
JOURNAL OF HOSPITAL INFECTION, 1991, 19 (02) :89-98
[2]   PSEUDOMONAS INFECTION OF THE BILIARY SYSTEM RESULTING FROM USE OF A CONTAMINATED ENDOSCOPE [J].
ALLEN, JI ;
ALLEN, MO ;
OLSON, MM ;
GERDING, DN ;
SHANHOLTZER, CJ ;
MEIER, PB ;
VENNES, JA ;
SILVIS, SE .
GASTROENTEROLOGY, 1987, 92 (03) :759-763
[3]  
ALLEN JI, 1987, GASTROENTEROLOGY, V93, P1451, DOI 10.1016/0016-5085(87)90297-6
[4]  
Alvarado CJ, 2000, AM J INFECT CONTROL, V28, P138
[5]  
ALVARADO CJ, 1991, AM J MED, V91, P272
[6]  
*AM C GOV IND HYG, 2001, THRESH LIM VAL CHEM
[7]   A MORE ACCURATE METHOD FOR MEASUREMENT OF TUBERCULOCIDAL ACTIVITY OF DISINFECTANTS [J].
ASCENZI, JM ;
EZZELL, RJ ;
WENDT, TM .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1987, 53 (09) :2189-2192
[8]  
*ASS PER REG NURS, 2002, REC PRACT HIGH LEV D, P211
[9]  
Association of Perioperative Registered Nurses, 2002, REC PRACT US CAR END, P229
[10]  
*ASTM, 2000, F151800 ASTM