Magnetic resonance imaging for stroke: Basis principles and clinical use.

被引:33
作者
Heiland, S [1 ]
Sartor, K [1 ]
机构
[1] Univ Heidelberg Klinikum, Abt Neuroradiol, D-69120 Heidelberg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1999年 / 171卷 / 01期
关键词
cerebral ischemia; perfusion-MRI; diffusion-MRI; MR angiography;
D O I
10.1055/s-1999-9889
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Stroke is the third leading cause of death. Until recently, no diagnostic technique was available that could reliably depict ischemic tissue within a therapeutically promising time window. Since the beginning of this decade, a fundamental change has taken place: Perfusion- and diffusion-MRI have shown to be capable of depicting the ischemic injury immediately after vessel occlusion. While perfusion MRI is sensitive to abnormalities in cerebral capillary blood flow (micro-circulation), diffusion MRI indicates tissue damage on a cellular level. Combining perfusion- and diffusion-MRI with standard MR techniques (T-2-weighted sequences, MR angiography) results in an MR protocol that is complementary and gives insight into both structural and functional parameters.
引用
收藏
页码:3 / 14
页数:12
相关论文
共 51 条
[1]   THRESHOLDS IN CEREBRAL-ISCHEMIA - THE ISCHEMIC PENUMBRA [J].
ASTRUP, J ;
SIESJO, BK ;
SYMON, L .
STROKE, 1981, 12 (06) :723-725
[3]   Enlargement of human cerebral ischemic lesion volumes measured by diffusion-weighted magnetic resonance imaging [J].
Baird, AE ;
Benfield, A ;
Schlaug, G ;
Siewert, B ;
Lovblad, KO ;
Edelman, RR ;
Warach, S .
ANNALS OF NEUROLOGY, 1997, 41 (05) :581-589
[4]  
BENFIELD Y, 1996, ISMRM 4 SCI M BOOK A, V4, P1344
[5]   Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise [J].
Benner, T ;
Heiland, S ;
Erb, G ;
Forsting, M ;
Sartor, K .
MAGNETIC RESONANCE IMAGING, 1997, 15 (03) :307-317
[6]   MECHANISM OF DETECTION OF ACUTE CEREBRAL-ISCHEMIA IN RATS BY DIFFUSION-WEIGHTED MAGNETIC-RESONANCE MICROSCOPY [J].
BENVENISTE, H ;
HEDLUND, LW ;
JOHNSON, GA .
STROKE, 1992, 23 (05) :746-754
[7]   THE WORLDWIDE PROBLEM OF STROKE [J].
BONITA, R ;
BEAGLEHOLE, R ;
ASPLUND, K .
CURRENT OPINION IN NEUROLOGY, 1994, 7 (01) :5-10
[8]   Fluid-attenuated inversion recovery (FLAIR) for assessment of cerebral infarction - Initial clinical experience in 50 patients [J].
BrantZawadzki, M ;
Atkinson, D ;
Detrick, M ;
Bradley, WG ;
Scidmore, G .
STROKE, 1996, 27 (07) :1187-1191
[9]   EFFECT OF BULK TISSUE MOTION ON QUANTITATIVE PERFUSION AND DIFFUSION MAGNETIC-RESONANCE-IMAGING [J].
CHENEVERT, TL ;
PIPE, JG .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :261-265
[10]   REPERFUSION FOLLOWING FOCAL STROKE HASTENS INFLAMMATION AND RESOLUTION OF ISCHEMIC INJURED TISSUE [J].
CLARK, RK ;
LEE, EV ;
WHITE, RF ;
JONAK, ZL ;
FEUERSTEIN, GZ ;
BARONE, FC .
BRAIN RESEARCH BULLETIN, 1994, 35 (04) :387-392