Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by highperformance liquid chromatography with tandem mass spectrometry

被引:67
作者
Jemal, M [1 ]
Teitz, D [1 ]
Ouyang, Z [1 ]
Khan, S [1 ]
机构
[1] Bristol Myers Squibb Pharmaceut Res Inst, Bioanalyt Res Metab & Pharmacokinet, New Brunswick, NJ 08903 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 1999年 / 732卷 / 02期
关键词
plasma sample purification;
D O I
10.1016/S0378-4347(99)00323-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three extraction procedures were developed for the quantitative determination of a carboxylic acid containing analyte (1) in human plasma by high-performance liquid chromatography (HPLC) with negative ion electrospray tandem mass spectrometry (MS-MS). The first procedure was based on the manual liquid-liquid extraction (LLE) of the acidified plasma samples with methyl tert-butyl ether. The second procedure was based on the automation of the manual LLE procedure using 96-well collection plates and a robotic liquid handling system. The third approach was based on automated solid-phase extraction (SPE) using 96-well SPE plates and a robotic liquid handling system. A lower limit of quantitation of 50 pg/ml was achieved using all three extraction procedures. The total time required to prepare calibration curve standards, aliquot the standards and plasma samples, and process a total of 96 standards and samples by manual LLE was three-times longer than the time required for 96-well SPE or 96-well LLE (4 h, 50 min vs. 1 h, 43 min). Even more importantly, the time the bioanalyst physically spent on the 96-well LLE or 96-well SPE procedure was only a small fraction of the time spent on the manual LLE procedure (<10 min vs. 4 h, 10 min). It should be noted that the 96-well SPE procedure incorporated the two steps of evaporation of the eluates to dryness and subsequent reconstitution of the dried extract. The total time required for the 96-well SPE could be reduced by 50% if the eluates were injected directly, eliminating the drying and reconstitution steps, which is achievable when sensitivity is less of an issue. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:501 / 508
页数:8
相关论文
共 15 条
[1]  
Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
[2]  
2-Q
[3]   Use of generic fast gradient liquid chromatography tandem mass spectroscopy in quantitative bioanalysis [J].
Ayrton, J ;
Dear, GJ ;
Leavens, WJ ;
Mallett, DN ;
Plumb, RS .
JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (02) :243-254
[4]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[5]  
2-Z
[6]   Automated 96-well solid phase extraction for the determination of doramectin in cattle plasma [J].
Harrison, AC ;
Walker, DK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (05) :777-783
[7]  
Jemal M, 1998, RAPID COMMUN MASS SP, V12, P1389, DOI 10.1002/(SICI)1097-0231(19981015)12:19<1389::AID-RCM329>3.3.CO
[8]  
2-K
[9]  
Jemal M, 1999, RAPID COMMUN MASS SP, V13, P97, DOI 10.1002/(SICI)1097-0231(19990130)13:2<97::AID-RCM461>3.0.CO
[10]  
2-T