Effect of storage media on the fluoride release and surface microhardness of four polyacid-modified composite resins ("compomers")

被引:72
作者
Geurtsen, W [1 ]
Leyhausen, G
Garcia-Godoy, F
机构
[1] Med Univ, Dept Conservat Dent & Periodontol, Hannover, Germany
[2] Univ Texas, Dept Restorat Dent, San Antonio, TX 78285 USA
[3] Univ Texas, Dept Pediat Dent, San Antonio, TX 78285 USA
关键词
polyacid-modified; composite resins; esterase treatment; fluoride release; microhardness;
D O I
10.1016/S0109-5641(99)00034-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The aims of this investigation were to measure the surface microhardness (Vickers) as well as the release of fluoride from four polyacid-modified composite resins (PMC) ("compomers") (Compoglass F, F 1080, Dyract AP, experimental compomer) after storage in various artificial saliva (buffers) including one esterase-buffer. Methods. Samples were stored for 6 days in de-ionized water, acidic buffer I (pH 4.2), neutral buffer II (pH 7.0), or neutral buffer IIT (pH 7.0) containing porcine esterase. The specimens were transferred into fresh media every 48 h, Fluoride release was measured every 48 h. Vickers hardness of each five samples of every group was determined before storing the samples in media (baseline) as well as after storage for 24, 48, and 144 h in the various solutions. Dry-stored specimens served as control, Results. The surface microhardness of all PMCs significantly decreased after storage in the various media. No significant differences,, however. were found between samples of the same material stored in the various media for 6 days. In general, the highest fluoride quantity was released into the acidic buffer I except for Dyract AP, which segregated similar quantities of fluoride into buffer I and into de-ionized water. More fluoride was released into de-ionized water than into neutral buffers. Further, esterase treatment increased fluoride release from three PMCs. Significance. Our results suggest that the action of salivary esterases may weaken the surface of polyacid-modified composite resin restorations. As a clinical consequence, wear may be enhanced and load resistance may be reduced. In addition, fluoride release from PMCs may be increased by hydrolytic enzymes in saliva and under acidic conditions. (C) 1999 Elsevier Science Academy of Dental Materials. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 32 条
[1]  
ARAUJO DB, 1996, OPER DENT, V21, P185
[2]  
ATTIN T, 1996, DTSCH ZAHNARZTL Z, V51, P675
[3]   EFFECT OF ESTERASE ON METHACRYLATES AND METHACRYLATE POLYMERS IN AN ENZYME SIMULATOR FOR BIODURABILITY AND BIOCOMPATIBILITY TESTING [J].
BEAN, TA ;
ZHUANG, WC ;
TONG, PY ;
EICK, JD ;
YOURTEE, DM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (01) :59-63
[4]   THE EFFECT OF STORAGE MEDIA UPON THE SURFACE MICROHARDNESS AND ABRASION RESISTANCE OF 3 COMPOSITES [J].
CHADWICK, RG ;
MCCABE, JF ;
WALLS, AWG ;
STORER, R .
DENTAL MATERIALS, 1990, 6 (02) :123-128
[5]   Influence of enzymes and plaque acids on in vitro wear of dental composites [J].
deGee, AJ ;
Wendt, SL ;
Werner, A ;
Davidson, CL .
BIOMATERIALS, 1996, 17 (13) :1327-1332
[6]  
El-Badrawy WA, 1998, OPER DENT, V23, P2
[7]   FLUORIDE RELEASE FROM GLASS-IONOMER CEMENTS IN DEIONIZED WATER AND ARTIFICIAL SALIVA [J].
ELMALLAKH, BF ;
SARKAR, NK .
DENTAL MATERIALS, 1990, 6 (02) :118-122
[8]   RELEASE OF FLUORIDE AND OTHER ELEMENTS FROM LIGHT-CURED GLASS IONOMERS IN NEUTRAL AND ACIDIC CONDITIONS [J].
FORSS, H .
JOURNAL OF DENTAL RESEARCH, 1993, 72 (08) :1257-1262
[9]   Resin-modified glass ionomer cements: Fluoride release and influence on Streptococcus mutans growth [J].
Friedl, KH ;
Schmalz, G ;
Hiller, KA ;
Shams, M .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1997, 105 (01) :81-85
[10]  
Garcia-Godoy F, 1993, J Clin Pediatr Dent, V17, P83