Evaluation of an enzyme-linked immunosorbent assay for determination of porcine haptoglobin

被引:20
作者
Petersen, HH
Nielsen, JP
Jensen, AL
Heegaard, PMH
机构
[1] Royal Vet & Agr Univ, Dept Clin Studies, DK-1870 Frederiksberg C, Denmark
[2] Danish Vet Lab, Dept Biochem & Immunol, DK-1790 Copenhagen, Denmark
来源
JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE | 2001年 / 48卷 / 09期
关键词
D O I
10.1046/j.1439-0442.2001.00377.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
An enzyme-linked immunosorbent assay for quantification of haptoglobin in porcine serum was evaluated. Tbe detection limit when expressed as the estimated concentration of a blank sample was 0.0003 mg/ml. The precision of the assay was acceptable with intra-assay coefficients of variation below 4 % and inter-assay coefficient of variation below 5 % for serum concentrations ranging from 1.0 mg/ml and above. For samples with a concentration below 0.8 mg/ml, the inter-assay coefficient of variation was above 10 %. The assay maintained linearity under dilution. Recovery was proportional. Haemolysis significantly decreased the measured concentration of haptoglobin in paired serum samples (one-sided t-test, P < 0.0001, degrees of freedom = 29). No significant effect on the concentration due to repeated freezing and thawing of serum was observed. The biological variation in individual pigs with no clinical signs of disease was estimated by, nested analysis of variance. Between-pig variation was 86.0 %, within-pig variation was 13.3 % an analytical variation was 0.7 %. The one-sided critical difference was 12.3 % and the mo-sided critical difference was 14.6 %. The index of individuality was 0.2. The maximum allowable analytical imprecision was 2.6 % and the maximum analytical inaccuracy was 9.9 %. The number of samples required to determine, the true haptoglobin value in an individual pig when accounting for the day-to-day fluctuation was 5. In conclusion, the haptoglobin assay was found to be suitable for quantification of haptoglobin in non-haemolysed porcine serum samples with a haptoglobin concentration above 1.0 mg/ml. The analytical variance was found to be low. The haptoglobin concentration in serum was found to characterize individual animals. A large inter-animal variation in haptoglobin level was found.
引用
收藏
页码:513 / 523
页数:11
相关论文
共 23 条
[1]   THE ACUTE-PHASE RESPONSE [J].
BAUMANN, H ;
GAULDIE, J .
IMMUNOLOGY TODAY, 1994, 15 (02) :74-80
[2]  
Box GEP., 1978, Statistics for experimenters
[3]   BIOLOGICAL VARIATION OF ACUTE-PHASE PROTEINS [J].
CLARK, GH ;
FRASER, CG .
ANNALS OF CLINICAL BIOCHEMISTRY, 1993, 30 :373-376
[4]   The acute phase response of acid soluble glycoprotein, alpha(1)-acid glycoprotein, ceruloplasmin, haptoglobin and C-reactive protein, in the pig [J].
Eckersall, PD ;
Saini, PK ;
McComb, C .
VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 1996, 51 (3-4) :377-385
[5]  
EURELL TE, 1992, CAN J VET RES, V56, P6
[6]  
Francisco C. J., 1996, Swine Health and Production, V4, P67
[7]  
Francisco CJ, 1996, CAN J VET RES, V60, P222
[8]   DESIRABLE PERFORMANCE STANDARDS FOR CLINICAL-CHEMISTRY TESTS [J].
FRASER, CG .
ADVANCES IN CLINICAL CHEMISTRY, 1983, 23 :299-339
[9]  
FRASER CG, 1988, ARCH PATHOL LAB MED, V112, P404
[10]  
FRASER CG, 1989, CRIT REV CL LAB SCI, V27, P409