Aseptic loosening of 2 rim-fix, hydroxyapatite-coated acetabular cups

被引:6
作者
Benkö, TZ [1 ]
Santiago-Martin, A [1 ]
Ruddlesdin, C [1 ]
Selzer, G [1 ]
机构
[1] Barnley Dist Gen Hosp, Dept Orthopaed & Trauma, Barnsley, England
关键词
hip; arthroplasty; acetabular component; hydroxyapatite (HA); loosening;
D O I
10.1054/arth.2002.32188
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Two cases of aseptic loosening in the 11th and 12th year of follow-up of the same acetabular component of a fully hydroxyapatite (HA)-coated total hip arthroplasty are presented. The acetabular cup was a rim-fix type, HA-coated, titanium hemispherical shell secured to the bony acetabulum with titanium screws at the peripheral polyethylene rim. The short-term and midterm results were good,with HA-coated total hip arthroplasties, but further studies are needed to investigate whether the >10-year survival of these cups is as good as the survival of cemented ones.
引用
收藏
页码:519 / 523
页数:5
相关论文
共 7 条
[1]
Hydroxyapatite-coated total hip femoral components in patients less than fifty years old - Clinical and radiographic results after five to eight years of follow-up [J].
Capello, WN ;
DAntonio, JA ;
Feinberg, JR ;
Manley, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1023-1029
[2]
FIXATION OF HIP PROSTHESES BY HYDROXYAPATITE CERAMIC COATINGS [J].
FURLONG, RJ ;
OSBORN, JF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :741-745
[3]
6-YEAR RESULTS OF HYDROXYAPATITE-COATED TOTAL HIP-REPLACEMENT [J].
GEESINK, RGT ;
HOEFNAGELS, NHM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (04) :534-547
[4]
Revision for aseptic loosening of uncemented cups in 4,352 primary total hip prostheses - A report from the Norwegian Arthroplasty Register [J].
Havelin, LI ;
Vollset, SE ;
Engesaeter, LB .
ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (06) :494-500
[5]
Total hip arthroplasty with hydroxyapatite-coated prostheses [J].
Jaffe, WL ;
Scott, DF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (12) :1918-1934
[6]
Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating [J].
Morscher, EW ;
Hefti, A ;
Aebi, U .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :267-272
[7]
The fully hydroxyapatite-coated total hip implant - Clinical and roentgenographic results [J].
Vedantam, R ;
Ruddlesdin, C .
JOURNAL OF ARTHROPLASTY, 1996, 11 (05) :534-542