Elementary analysis of petroleum distillates by GC-AED: Validation and application to the calculation of distillation profile properties

被引:5
作者
Baco, F
Quignard, A
Szymanski, R
机构
[1] CEDI Rene Navarre, Inst Francais Petr, F-69390 Vernaison, France
[2] Inst Francais Petr, F-92852 Rueil Malmaison, France
来源
OIL & GAS SCIENCE AND TECHNOLOGY-REVUE D IFP ENERGIES NOUVELLES | 1999年 / 54卷 / 04期
关键词
analysis; GC-AED; simulated distillation; distillates; characterisation; profile; properties; correlation;
D O I
10.2516/ogst:1999041
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article describes the development of elementary analysis in the distillation profile of petroleum cuts by gas phase chromatography-atomic emission detection (GC-AED) coupling and shows the application perspectives to characterisation of middle distillates of a piece of information unheard of until now. oil a routine basis. The performances of the analytical assembly used have been studied for carbon, hydrogen, sulphur and nitrogen analysis. Simulated distillation, a gas phase chromatography analysis which enables determining the weight percentage of distilled matter in relation to the boiling point of petroleum cuts, has been adapted to GC-AED coupling. We have developed a method giving access to three types of information. global elementary composition, simulated distillation and elementary composition in distillation profile, i.e. by fraction (%) of the distilled product. The analysis of the atmospheric distillates has been assessed in terms of precision and bias for these various types of information. The validation was carried out notably by comparison with rite results obtained using reference analytical methods, on pr preparative distillation cuts of representative samples. The application of GC-AED to characterisation of distillates is discussed in particular for classification purposes and for predicting petroleum properties in the distillation profile. The cetane number of gas oils was taken as an example to illustrate the latter application.
引用
收藏
页码:473 / 485
页数:13
相关论文
共 13 条
[1]  
[Anonymous], 1999, ANN BOOK ASTM STAND, P1
[2]  
[Anonymous], 1999, ANN BOOK ASTM STAND, V03.01
[3]  
*ASTM, 1996, ANN BOOK ASTM STAND, P353
[4]  
*ASTM, 1999, ANN BOOK ASTM STAND, P220
[5]  
BACO F, 1993, THESIS C BERNARD U L
[6]  
BACO F, 1997, THESIS C BERNARD U L
[7]  
FAFET A, 1995, IFP B, V50, P3
[8]  
GAUTHIER S, 1995, IFP B, V50, P2
[9]  
MAGNEDRISCH J, 1995, THESIS P M CURIE U P
[10]   EVALUATION OF A MICROWAVE CAVITY, DISCHARGE-TUBE, AND GAS-FLOW SYSTEM FOR COMBINED GAS-CHROMATOGRAPHY ATOMIC EMISSION DETECTION [J].
QUIMBY, BD ;
SULLIVAN, JJ .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1027-1034