Selective continuous monitoring and analysis of mixtures of acesulfame-K, cyclamate, and saccharin in artificial sweetener tablets, diet soft drinks, yogurts, and wines using filter-supported bilayer lipid membranes

被引:13
作者
Nikolelis, DP [1 ]
Pantoulias, S [1 ]
机构
[1] Univ Athens, Analyt Chem Lab, Dept Chem, GR-15771 Athens, Greece
关键词
D O I
10.1021/ac010559x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes a technique for the rapid and sensitive electrochemical flow injection monitoring and analysis of mixtures of the artificial sweeteners acesulfame-K, cyclamate, and saccharin using stabilized systems of filter-supported bilayer lipid membranes (BLMs). Injections of artificial sweeteners were made into flowing streams of a carrier electrolyte solution, and a transient current signal with duration of seconds reproducibly appeared in less than < 1 min after exposure of the lipid membranes to the artificial sweeteners. The magnitude of this signal was linearly related to the concentration of artificial sweeteners, which could be determined at micromolar levels. Repetitive cycles of injection of artificial sweeteners have shown no signal degradation during each cycle (30 sequential injections)., The time of appearance of the transient response was different for each artificial sweetener and increased in the order of cyclamic acid, acesulfame-K, and saccharin. The difference in time of response has allowed selective detection and analysis of these artificial sweeteners in mixtures. The effect of potent interferences, including a Aide range of compounds usually found in foods, proteins, and lipids was investigated. The results showed no interferences from these constituents of real food samples. The major interference from proteins (most common in lipid-film-based biosensors) can be eliminated by modulation of the carrier solution that does not allow adsorption of these compounds in BLMs. The technique was applied in real food samples, that is, in artificial sweetener tablets, diet soft drinks, wines, and yogurts that contain mixtures of these artificial sweeteners with aspartame and other compounds. A comparison of results using the present method and that of an Official Method of Analysis showed good agreement between the two methods.
引用
收藏
页码:5945 / 5952
页数:8
相关论文
共 25 条
[1]  
[Anonymous], 1996, MERCK IND
[2]  
*AOAC, 1995, OFF METH AN ASS OFF, P44
[3]   ANALYSIS OF SACCHARIN, ACESULFAME-K AND SODIUM CYCLAMATE BY HIGH-PERFORMANCE ION CHROMATOGRAPHY [J].
BIEMER, TA .
JOURNAL OF CHROMATOGRAPHY, 1989, 463 (02) :463-468
[4]  
Fatibello-Filho O, 1997, ANAL LETT, V30, P1653, DOI 10.1080/00032719708001684
[5]   Development of a capillary electrophoresis method for the simultaneous analysis of artificial sweeteners, preservatives and colours in soft drinks [J].
Frazier, RA ;
Inns, EL ;
Dossi, N ;
Ames, JM ;
Nursten, HE .
JOURNAL OF CHROMATOGRAPHY A, 2000, 876 (1-2) :213-220
[6]  
HILLE B, 1992, IONIC CHANNELS EXCIT, P4
[7]  
LAWRENCE JF, 1988, J ASSOC OFF ANA CHEM, V71, P934
[8]  
Nikolelis DP, 1999, ELECTROANAL, V11, P7, DOI 10.1002/(SICI)1521-4109(199901)11:1<7::AID-ELAN7>3.0.CO
[9]  
2-F
[10]   BILAYER-LIPID MEMBRANES FOR ELECTROCHEMICAL SENSING [J].
NIKOLELIS, DP ;
KRULL, UJ .
ELECTROANALYSIS, 1993, 5 (07) :539-545