A new D-dimer cutoff in bedridden hospitalized elderly patients

被引:22
作者
Granziera, Serena [1 ]
Rechichi, Alfonsina [1 ]
De Rui, Marina [1 ]
De Carlo, Paola [1 ]
Bertozzo, Giulia [1 ]
Marigo, Lucia [1 ]
Nante, Giovanni [1 ]
Manzato, Enzo [1 ]
机构
[1] Univ Padua, Osped Giustinianeo, Dept Med, Div Geriatr, Padua, Italy
关键词
bedridden; cutoff; D-dimer; deep vein thrombosis; doppler ultrasound; elderly; venous thromboembolism; DEEP-VEIN THROMBOSIS; ILL MEDICAL PATIENTS; VENOUS THROMBOSIS; DIAGNOSTIC-ACCURACY; DOPPLER ULTRASOUND; TADEUS PROJECT; THROMBOEMBOLISM; METAANALYSIS; EXCLUSION; ULTRASONOGRAPHY;
D O I
10.1097/MBC.0b013e3283566adb
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Asymptomatic deep vein thrombosis (DVT) and pulmonary embolism are leading causes of morbidity following the hospitalization of elderly people. The diagnosis of DVT is supported by the D-dimer laboratory assay. The concentration of D-dimer increases in patients with DVT, but may be high in other conditions too (i.e. cancer, infections and inflammation). Old age coincides with a physiological increase in D-dimer values, and that is why D-dimer assay in the elderly is characteristically highly sensitive but scarcely specific. The aim of our study was to explore the reliability of different D-dimer cutoffs for the diagnosis of asymptomatic DVT in a population of bedridden hospitalized elderly patients. We studied 199 patients who were a mean 86.3 +/- 6.7 years old. All participants underwent lower limb Doppler ultrasound (DUS) and D-dimer venous blood sampling on admission. In our cohort, the usual cutoff proved highly sensitive (100%), but its specificity was very poor (20.1%). To find a higher cutoff that could improve the method's specificity, we analyzed our data using a receiver operating characteristic curve analysis. The resulting D-dimer cutoff of 492 mu g/l enabled us to retain the same sensitivity while improving the test's specificity to 39.1%, with a consequent improvement in its positive predictive value and accuracy. In addition to improving the method's reliability, this result may be helpful in clinical practice, in both medical wards and nursing homes. By adopting a cutoff of 492 mu g/l, clinicians could significantly increase the proportion of older patients in whom DVT can be safely ruled out, reducing referrals for DUS and administration of heparin, with consequent clinical, practical and economic advantages. Blood Coagul Fibrinolysis 24:109-112 (C) 2013 Wolters Kluwer Health | Lippincott Williams & Wilkins.
引用
收藏
页码:109 / 112
页数:4
相关论文
共 21 条
[1]
Guidelines for the Diagnosis, Treatment and Prevention of Pulmonary Thromboembolism and Deep Vein Thrombosis (JCS 2009) - Digest Version [J].
Ando, Motomi ;
Fukuda, Ikuo ;
Ito, Masaaki ;
Kobayashi, Takao ;
Masuda, Masahisa ;
Miyahara, Yoshiyuki ;
Nakanishi, Norifumi ;
Niwa, Akihiro ;
Ohgi, Shigetsugu ;
Tajima, Hiroyuki ;
Ishibashi, Hiroyuki ;
Kanaoka, Yasushi ;
Nakamura, Mashio ;
Sakuma, Masahito ;
Satoh, Toru ;
Tanabe, Nobuhiro ;
Yamada, Norikazu ;
Yamashita, Mitsuru ;
Kuriyama, Takayuki ;
Matsubara, Junichi ;
Nakano, Takeshi ;
Ozaki, Yukio ;
Sakata, Ryuzo .
CIRCULATION JOURNAL, 2011, 75 (05) :1258-1281
[2]
Ruling out the diagnosis of venous thromboembotism in the elderly: is it time to revise the role of D-dimer? [J].
Antonelli, Fabio ;
Villani, Luciano ;
Masotti, Luca ;
Landini, Giancarlo .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2007, 25 (06) :727-728
[3]
Diagnostic accuracy of compression ultrasonography for the detection of asymptomatic deep venous thrombosis in medical patients - The TADEUS project [J].
Bressollette, L ;
Nonent, M ;
Oger, E ;
Garcia, JF ;
Larroche, P ;
Gulas, B ;
Scarabin, PY ;
Mottier, D .
THROMBOSIS AND HAEMOSTASIS, 2001, 86 (02) :529-533
[4]
COGO A, 1993, THROMB HAEMOSTASIS, V70, P404
[5]
Diagnostic accuracy of D-dimer test for exclusion of venous thromboembolism:: a systematic review [J].
Di Nisio, M. ;
Squizzato, A. ;
Rutjes, A. W. S. ;
Buller, H. R. ;
Zwinderman, A. H. ;
Bossuyt, P. M. M. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 (02) :296-304
[6]
The use of power Doppler ultrasound in the diagnosis of isolated deep venous thrombosis of the calf [J].
Forbes, K ;
Stevenson, AJM .
CLINICAL RADIOLOGY, 1998, 53 (10) :752-754
[7]
An evaluation of rapid D-dimer assays for the exclusion of deep vein thrombosis [J].
Gardiner, C ;
Pennaneac'h, C ;
Walford, C ;
Machin, SJ ;
Mackie, IJ .
BRITISH JOURNAL OF HAEMATOLOGY, 2005, 128 (06) :842-848
[8]
Excluding venous thromboembolism using point of care D-dimer tests in outpatients: a diagnostic meta-analysis [J].
Geersing, G. J. ;
Janssen, K. J. M. ;
Oudega, R. ;
Bax, L. ;
Hoes, A. W. ;
Reitsma, J. B. ;
Moons, K. G. M. .
BMJ-BRITISH MEDICAL JOURNAL, 2009, 339 :450
[9]
Meta-analysis: The value of clinical assessment in the diagnosis of deep venous thrombosis [J].
Goodacre, S ;
Sutton, AJ ;
Sampson, FC .
ANNALS OF INTERNAL MEDICINE, 2005, 143 (02) :129-139
[10]
D-dimer concentration increases with age reducing the clinical value of the D-dimer assay in the elderly [J].
Harper, P. L. ;
Theakston, E. ;
Ahmed, J. ;
Ockelford, P. .
INTERNAL MEDICINE JOURNAL, 2007, 37 (09) :607-613