How should the acetabular angle of sharp be measured on a pelvic radiograph?

被引:43
作者
Agus, H [1 ]
Biçimoglu, A [1 ]
Ömeroglu, H [1 ]
Tümer, Y [1 ]
机构
[1] SSK Tepecik Hosp, Clin Orthopaed & Traumatol 2, Izmir, Turkey
关键词
acetabular angle; hip dysplasia; intraobserver and interobserver reliability radiographic measurement; sourcil;
D O I
10.1097/00004694-200203000-00020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Four experienced orthopaedic surgeons measured the acetabular angle of Sharp (AA) in 66 hips by using two methods. In the classic method (AA-c), the lateral margin of the acetabular roof was used as the landmark. In the modified method (AA-m), the lateral margin of the sourcil (subchondral bony condensation in the acetabular roof) was used as the landmark. Mean AA-c and AA-m measurements were 44.8degrees and 48.4degrees, respectively. Mean intraobserver variations of AA-c and AA-m were 1.8degrees and 2.1degrees, respectively. Mean interobserver variations of AA-c and AA-m Were 2.1degrees and 2.6degrees, respectively. Means obtained using AA-c of normal and defective acetabular roofs were similar, but the difference between AA-m means of different acetabular roof types was significant. The authors conclude that both AA-c and AA-in were reliable measurement methods, but clinical use of AA-m would probably produce better understanding of the radiographic hip anatomy in dysplastic hips.
引用
收藏
页码:228 / 231
页数:4
相关论文
共 14 条
[1]
COOPERMAN DR, 1983, CLIN ORTHOP RELAT R, P79
[2]
[3]
Chiari osteotomy and shelf augmentation in the treatment of hip dysplasia [J].
Fong, HC ;
Lu, W ;
Li, YH ;
Leong, JCY .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2000, 20 (06) :740-744
[4]
Diagnosing childhood acetabular dysplasia using the lateral margin of the sourcil [J].
Kim, HT ;
Kim, JI ;
Yoo, CI .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2000, 20 (06) :709-717
[5]
Modified Chiari osteotomy for arthrosis after Perthes' disease - 14 hips followed for 2-12 years [J].
Koyama, K ;
Higuchi, F ;
Inoue, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (02) :129-132
[6]
Ma RX, 1997, CHINESE MED J-PEKING, V110, P346
[7]
NAKAMURA S, 1989, CLIN ORTHOP RELAT R, P190
[8]
Reliability of radiological measurements in the assessment of hip dysplasia in adults [J].
Nelitz, M ;
Guenther, KP ;
Gunkel, S ;
Puhl, W .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (856) :331-334
[9]
THE ACCURACY OF MEASUREMENT OF LENGTH AND ANGLES IN THE X-RAY AND ULTRASOUND IMAGE OF THE INFANTILE HIP-JOINT [J].
NIETHARD, FU ;
ROESLER, H .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1987, 125 (02) :170-176
[10]
OGATA S, 1990, J BONE JOINT SURG BR, V72, P190