摘要
In the framework of the development of new techniques, the ability of laser-induced breakdown spectroscopy (LIBS) to analyse remotely complex aqueous solutions was investigated. The jet configuration with a collimated gas stream was chosen because it appeared to be the most promising method for the LIBS probe, particularly in terms of sensitivity and repeatability. For emission collection, the echelle spectrometer offers a simultaneously recorded wavelength range from the UV to the near IR and is interesting for multielemental analysis for LIBS and also for inductively coupled plasma (ICP) optical emission spectroscopy (OES). The importance of parameters influencing the quantitative results of LIBS such as multispecies analysis, sheath gas, use of an internal standard and temporal parameters for analysis is described. LIBS quantitative data have been directly compared with results from the more standard ICP/OES technique.
引用
收藏
页码:338 / 344
页数:7
相关论文
共 37 条
[1]   Trace element analysis in water by the laser-induced breakdown spectroscopy technique [J].
Arca, G ;
Ciucci, A ;
Palleschi, V ;
Rastelli, S ;
Tognoni, E .
APPLIED SPECTROSCOPY, 1997, 51 (08) :1102-1105
[2]   EVALUATION OF AN ISOLATED DROPLET SAMPLE INTRODUCTION SYSTEM FOR LASER-INDUCED BREAKDOWN SPECTROSCOPY [J].
ARCHONTAKI, HA ;
CROUCH, SR .
APPLIED SPECTROSCOPY, 1988, 42 (05) :741-746
[3]   Laser-induced breakdown spectroscopy of liquids: Aqueous solutions of nickel and chlorinated hydrocarbons [J].
Berman, LM ;
Wolf, PJ .
APPLIED SPECTROSCOPY, 1998, 52 (03) :438-443
[4]   ANALYSIS OF MONO-ATOMIC IONS IN INDIVIDUAL FLUID INCLUSIONS BY LASER-PRODUCED PLASMA EMISSION-SPECTROSCOPY [J].
BOIRON, MC ;
DUBESSY, J ;
ANDRE, N ;
BRIAND, A ;
LACOUR, JL ;
MAUCHIEN, P ;
MERMET, JM .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1991, 55 (03) :917-923
[5]   Panoramic laser-induced breakdown spectrometry of water [J].
Charfi, B ;
Harith, MA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (07) :1141-1153
[6]   SINGLE-SHOT ELEMENTAL ANALYSIS OF LIQUIDS BASED ON LASER VAPORIZATION AT FLUENCES BELOW BREAKDOWN [J].
CHEUNG, NH ;
YEUNG, ES .
APPLIED SPECTROSCOPY, 1993, 47 (07) :882-886
[7]   SPECTROCHEMICAL ANALYSIS OF LIQUIDS USING THE LASER SPARK [J].
CREMERS, DA ;
RADZIEMSKI, LJ ;
LOREE, TR .
APPLIED SPECTROSCOPY, 1984, 38 (05) :721-729
[8]   Trace element analysis in water by LIBS technique [J].
D 'Angelo, C ;
Gomba, J ;
Iriarte, D ;
Bertuccelli, G .
3RD IBEROAMERICAN OPTICS MEETING AND 6TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND THEIR APPLICATIONS, 1999, 3572 :534-541
[9]   Analysis by laser-induced breakdown spectroscopy of complex solids, liquids, and powders with an echelle spectrometer [J].
Fichet, P ;
Menut, D ;
Brennetot, R ;
Vors, E ;
Rivoallan, A .
APPLIED OPTICS, 2003, 42 (30) :6029-6035
[10]   Quantitative elemental determination in water and oil by laser induced breakdown spectroscopy [J].
Fichet, P ;
Mauchien, P ;
Wagner, JF ;
Moulin, C .
ANALYTICA CHIMICA ACTA, 2001, 429 (02) :269-278