CT-directed microcoil localization of small peripheral lung nodules: A feasibility study in pigs

被引:14
作者
Jangra, D
Powell, T
Kalloger, SE
Guerra, HL
Clifton, J
Coxson, HO
Finley, RJ
Mayo, JR
机构
[1] Vancouver Hosp, Dept Surg, Vancouver, BC, Canada
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Vancouver Hosp, Dept Radiol, Vancouver, BC, Canada
[4] Vancouver Hosp, Dept Surg, Vancouver, BC, Canada
[5] Vancouver Hosp, James Hogg iCAPTURE Ctr Cardiovasc & Pulm Res, Vancouver, BC, Canada
关键词
CT scanning; localization; lung cancer;
D O I
10.1080/08941930500248946
中图分类号
R61 [外科手术学];
学科分类号
摘要
Platinum microcoils were placed in porcine lungs to determine the feasibility for use as a lung nodule marker. Using computed tomography (CT) guidance, the microcoils were successfully deployed in 17 out of 19 attempts. Coil deployment depth ranged from 7 mm to 34 mm below the pleural surface. Moderate pneumothorax was detected after 3 of 19 microcoil insertions. No hemothorax or significant pulmonary hemorrhage was noted. Fluoroscopic guided thoracoscopic resection was successful in 10 of 12 attempts. Platinum microcoils can be safely and easily deployed into the lung parenchyma with minimal complication risk, and can be used to guide subsequent thoracoscopic wedge resection.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 32 条
[1]
Thoracoscopic lung resection for extremely small nodular lesions using simultaneous intraoperative real-time computed tomography [J].
Akamatsu, H ;
Sunamori, M ;
Katsuo, K .
THORACIC AND CARDIOVASCULAR SURGEON, 2000, 48 (01) :34-35
[2]
A pilot study of the role of TC-99 radionuclide in localization of pulmonary nodular lesions for thoracoscopic resection [J].
Chella, A ;
Lucchi, M ;
Ambrogi, MC ;
Menconi, G ;
Melfi, FMA ;
Gonfiotti, A ;
Boni, G ;
Angeletti, CA .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 18 (01) :17-21
[3]
Pulmonary nodules: CT-guided contrast material localization for thoracoscopic resection [J].
Choi, BG ;
Kim, HK ;
Kim, BS ;
Kim, KT ;
Shinn, KS ;
Moon, SW .
RADIOLOGY, 1998, 208 (02) :399-401
[4]
Coxson HO, 2002, RADIOLOGY, V225, P293
[5]
Preoperative localization of small pulmonary lesions with a short hook wire and suture system: Experience with 168 procedures [J].
Dendo, S ;
Kanazawa, S ;
Ando, A ;
Hyodo, T ;
Kouno, Y ;
Yasui, K ;
Mimura, H ;
Akaki, S ;
Kuroda, M ;
Shimizu, N ;
Hiraki, Y .
RADIOLOGY, 2002, 225 (02) :511-518
[6]
Eckersberger F, 1997, Langenbecks Arch Chir Suppl Kongressbd, V114, P246
[7]
Gagliano RA., 1999, CURR SURG, V56, P410, DOI [10.1016/S0149-7944(99)00169-5, DOI 10.1016/S0149-7944(99)00169-5]
[8]
Sonographic guidance for the localization of peripheral pulmonary nodules during thoracoscopy [J].
Greenfield, AL ;
Steiner, RM ;
Liu, JB ;
Cohn, HE ;
Goldberg, BB ;
Rawool, NM ;
Merton, DA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (04) :1057-1060
[9]
Massive gas embolism during pulmonary nodule hook wire localization [J].
Horan, TA ;
Pinheiro, PM ;
Araújo, LM ;
Santiago, FF ;
Rodrigues, MR .
ANNALS OF THORACIC SURGERY, 2002, 73 (05) :1647-1649
[10]
JANGRA D, 2003, LUNG CANCER, V41, pS193