Parameter study on performance of building cooling by night-time ventilation

被引:108
作者
Artmann, N. [1 ]
Manz, H. [1 ]
Heiselberg, P. [2 ]
机构
[1] Empa, Swiss Fed Labs Mat Testing & Res, Lab Bldg Technol, CH-8600 Dubendorf, Switzerland
[2] Univ Aalborg, Dept Civil Engn, Hybrid Ventilat Ctr, DK-9000 Aalborg, Denmark
关键词
passive cooling; night-time ventilation; parameter study; thermal mass; heat transfer; climate;
D O I
10.1016/j.renene.2008.02.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Especially for commercial buildings in moderate climates, night-time ventilation seems to be a simple and energy-efficient approach to improve thermal comfort in summer. However, due to uncertainties in the prediction of thermal comfort in buildings with night-time ventilation, architects and engineers are still hesitant to apply this technique. In order to reduce the uncertainties, the most important parameters affecting night ventilation performance need to be identified. A typical office room was therefore modelled using a building energy simulation programme (HELIOS), and the effect of different parameters such as building construction, heat gains, air change rates heat transfer coefficients and, climatic conditions including annual variations on the number of overheating degree hours (operative room temperature >26 degrees C) was evaluated. Climatic conditions and air flow rate during night-time ventilation were found to have the largest effect. But thermal mass and internal heat gains also have a significant effect on cooling performance and the achievable level of thermal comfort. Using this modelling approach, significant sensitivity to heat transfer was found only for total heat transfer coefficients below about 4 W/m(2) K. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2589 / 2598
页数:10
相关论文
共 34 条
[1]   ON THE USE OF THE ATMOSPHERIC HEAT SINKS FOR HEAT DISSIPATION [J].
AGAS, G ;
MATSAGGOS, T ;
SANTAMOURIS, M ;
ARGYRIOU, A .
ENERGY AND BUILDINGS, 1991, 17 (04) :321-329
[2]   THE EFFECT OF VARIATIONS IN CONVECTION COEFFICIENTS ON THERMAL-ENERGY STORAGE IN BUILDINGS .1. INTERIOR PARTITION WALLS [J].
AKBARI, H ;
SAMANO, D ;
MERTOL, A ;
BAUMAN, F ;
KAMMERUD, R .
ENERGY AND BUILDINGS, 1986, 9 (03) :195-211
[3]  
[Anonymous], 1997, 6946 EN ISO
[4]  
[Anonymous], 2004, 13791 EN ISO
[5]   Impact of climate warming on passive night cooling potential [J].
Artmann, N. ;
Gyalistras, D. ;
Manz, H. ;
Heiselberg, P. .
BUILDING RESEARCH AND INFORMATION, 2008, 36 (02) :111-128
[6]   Climatic potential for passive cooling of buildings by night-time ventilation in Europe [J].
Artmann, N. ;
Manz, H. ;
Heiselberg, P. .
APPLIED ENERGY, 2007, 84 (02) :187-201
[7]   Night ventilation for building cooling in summer [J].
Blondeau, P ;
Sperandio, M ;
Allard, F .
SOLAR ENERGY, 1997, 61 (05) :327-335
[8]  
Blondeau P., 1994, P EUR C EN PERF IND, V3, P854
[9]   Passive cooling in a low-energy office building [J].
Breesch, H ;
Bossaer, A ;
Janssens, A .
SOLAR ENERGY, 2005, 79 (06) :682-696
[10]  
BREESCH H, 2004, ROOMV 2004 C COIMBR