Non-enzymatic glucose biosensor based on overoxidized polypyrrole nanofiber electrode modified with cobalt(II) phthalocyanine tetrasulfonate

被引:134
作者
Ozcan, Levent [1 ]
Sahin, Yuecel [1 ]
Turk, Hayrettin [1 ]
机构
[1] Anadolu Univ, Dept Chem, Fac Sci, TR-26470 Tepebasi, Eskisehir, Turkey
关键词
Overoxidized polypyrrole; Biosensor; Cobalt(II) phthalocyanine; Glucose; Electrocatalysis;
D O I
10.1016/j.bios.2008.05.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An enzymeless biosensor, based on electrode position of overoxidized polypyrrole nanofiber onto pencil graphite electrode and modified with cobalt(II) phthalocyanine tetrasulfonate (CoPcTS), was investigated in this study. CoPcTS showed electrocatalytic activity for the oxidation of glucose in alkaline solution. The electrochemical performance of the modified electrodes was investigated by differential pulse voltammetric (DPV) method. The resulting biosensor exhibited excellent performance for glucose determination with a wide linear range (0.25-20 mM), a highly reproducible response (R.S.D. of 2.7%), low percentage of the interferences and long-term stability. The calculated detection limit was 0.1 mM at 3 sigma. in order to verify the reliability of the biosensor, it was applied to the determination of glucose in serum samples. The results were satisfactory and agreed closely with those measured in a hospital. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:512 / 517
页数:6
相关论文
共 52 条
[1]  
Aguirre MJ, 2002, ELECTROANAL, V14, P356, DOI 10.1002/1521-4109(200203)14:5<356::AID-ELAN356>3.0.CO
[2]  
2-U
[3]   Trends in reactivity of unsubstituted and substituted cobalt-phthalocyanines for the electrocatalysis of glucose oxidation [J].
Barrera, Cristian ;
Zhukov, Igor ;
Villagra, Evelyn ;
Bedioui, Fethi ;
Paez, Maritza A. ;
Costamagna, Juan ;
Zagal, Jose H. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 589 (02) :212-218
[4]   Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon ink incorporating glucose oxidase [J].
Crouch, E ;
Cowell, DC ;
Hoskins, S ;
Pittson, RW ;
Hart, JP .
ANALYTICAL BIOCHEMISTRY, 2005, 347 (01) :17-23
[5]   Pt-Pb alloy nanoparticle/carbon nanotube nanocomposite: a strong electrocatalyst for glucose oxidation [J].
Cui, Hui-Fang ;
Ye, Jian-Shan ;
Liu, Xiao ;
Zhang, Wei-De ;
Sheu, Fwu-Shan .
NANOTECHNOLOGY, 2006, 17 (09) :2334-2339
[6]  
Eggins B.R., 2003, CHEM SENSORS BIOSENS, P111
[7]   Prediction and characterization of the charge/size exclusion properties of over-oxidized poly(pyrrole) films [J].
Farrington, AM ;
Slater, JM .
ELECTROANALYSIS, 1997, 9 (11) :843-847
[8]   Voltammetric behavior and square-wave voltammetric determination of trepibutone at a pencil graphite electrode [J].
Gao, W ;
Song, JF ;
Wu, NY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 576 (01) :1-7
[9]   THE INFLUENCE OF OVEROXIDATION TREATMENT ON THE PERMEABILITY OF POLYPYRROLE FILMS [J].
GAO, ZQ ;
ZI, MX ;
CHEN, BS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 373 (1-2) :141-148
[10]   The role of continuous glucose sensors in diabetes care [J].
Garg, SK ;
Hoff, HK ;
Chase, HP .
ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2004, 33 (01) :163-+