Extracardiac ablation of the canine atrioventricular junction by use of high-intensity focused ultrasound

被引:56
作者
Strickberger, SA
Tokano, T
Kluiwstra, JUA
Morady, F
Cain, C
机构
[1] Univ Michigan, Ctr Med, Div Cardiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
xablation; atrioventricular node; arrhythmias;
D O I
10.1161/01.CIR.100.2.203
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-High-intensity focused ultrasound has been applied to internal organs from outside the body to ablate tissue. No published study has assessed the feasibility of ablating cardiac tissue within the beating heart by use of this type of therapeutic ultrasound. The purpose of this study was to determine whether high-intensity focused ultrasound can be used to ablate the atrioventricular (AV) junction within the beating heart. Methods and Results-Ten dogs were anesthetized and underwent a thoracotomy. The heart was covered with a polyvinyl chloride membrane. The thorax above the membrane was perfused with degassed water, which functioned as a coupling medium for the ultrasound. A 7.0-MHz diagnostic ultrasound probe was affixed to a spherically focused 1.4-MHz high-intensity focused ultrasound transducer with a 1.1X8.3-mm focal zone 63.5 mm from the ablation transducer. The diagnostic ultrasound probe was calibrated such that the location of the focal zone of the ablation transducer was identifiable on the 2-dimensional ultrasound image. Target sites were identified with the diagnostic ultrasound. The maximum ultrasound intensity for ablation (2.8 kW/cm(2)) was delivered to the AV junction only during electrical diastole and for a total of 30 seconds. Complete AV block was achieved in each of the 10 dogs with 6.5+/-5.6 (range, 3 to 21) 30-second applications of therapeutic ultrasound. Gross inspection showed that the mean lesion volume was 124+/-43 mm(3), with a depth of 6.7=/-3.6 mm, a length of 5.7+/-2.5 mm, and a width of 4.7+/-1.8 mm, Four hours after the dogs were killed, histopathological study demonstrated a well-demarcated area of necrosis and early inflammation. Conclusions-High-intensity focused ultrasound produces well-demarcated lesions and appears to be a feasible energy source to create complete AV block within the beating heart without damaging the overlying or underlying cardiac tissue. This energy source may allow for a noninvasive approach to ablation of cardiac arrhythmias.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 27 条
[1]   Noninvasive in vivo clot dissolution without a thrombolytic drug - Recanalization of thrombosed iliofemoral arteries by transcutaneous ultrasound combined with intravenous infusion of microbubbles [J].
Birnbaum, Y ;
Luo, H ;
Nagai, T ;
Fishbein, MC ;
Peterson, TM ;
Li, SP ;
Kricsfeld, D ;
Porter, TR ;
Siegel, RJ .
CIRCULATION, 1998, 97 (02) :130-134
[2]   RADIOFREQUENCY CATHETER ABLATION GUIDED BY INTRACARDIAC ECHOCARDIOGRAPHY [J].
CHU, E ;
FITZPATRICK, AP ;
CHIN, MC ;
SUDHIR, K ;
YOCK, PG ;
LESH, MD .
CIRCULATION, 1994, 89 (03) :1301-1305
[3]   HUMAN CANCER-TREATMENT WITH ULTRASOUND [J].
CORRY, PM ;
JABBOURY, K ;
ARMOUR, EP ;
KONG, JS .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1984, 31 (05) :444-456
[4]   THERAPEUTIC APPLICATIONS OF ULTRASOUND - A REVIEW [J].
DRILLER, J ;
LIZZI, FL .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1987, 6 (04) :33-40
[5]   ULTRASONIC THRESHOLD DOSAGES FOR MAMMALIAN CENTRAL NERVOUS SYSTEM [J].
DUNN, F ;
FRY, FJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1971, BM18 (04) :253-&
[6]   THRESHOLD DOSAGES FOR DAMAGE TO MAMMALIAN LIVER BY HIGH-INTENSITY FOCUSED ULTRASOUND [J].
FRIZZELL, LA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (05) :578-581
[7]  
FRY F J, 1970, Journal of the Acoustical Society of America, V48, P1413, DOI 10.1121/1.1912301
[8]   ULTRASONIC LESIONS IN THE MAMMALIAN CENTRAL NERVOUS SYSTEM [J].
FRY, WJ ;
BARNARD, JW ;
FRY, FJ ;
KRUMINS, RF ;
BRENNAN, JF .
SCIENCE, 1955, 122 (3168) :517-518
[9]  
GOSS SA, 1984, IEEE ULTRASONICS S, P743
[10]   TISSUE HEATING DURING RADIOFREQUENCY CATHETER ABLATION - A THERMODYNAMIC MODEL AND OBSERVATIONS IN ISOLATED PERFUSED AND SUPERFUSED CANINE RIGHT VENTRICULAR FREE WALL [J].
HAINES, DE ;
WATSON, DD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (06) :962-976