Time-frequency analysis of pulsed eddy current signals

被引:67
作者
Safizadeh, MS
Lepine, BA
Forsyth, DS
Fahr, A
机构
[1] Natl Res Council Canada, Inst Aerosp Res, Struct Mat & Prop Lab, Ottawa, ON K1A 0R6, Canada
[2] NovaMetrics, Kanata, ON K7L 1N6, Canada
关键词
pulsed eddy current; nondestructive inspection; time-frequency analysis; lap joint corrosion;
D O I
10.1023/A:1012244208475
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Detection and measurement of the material loss due to corrosion in aircraft fuselage lap splices are of great importance to life management of ageing aircraft. Pulsed eddy current (PEC) techniques have shown the potential to fully characterise these structures. However, variations in the probe lift-off, the interlayer gaps and material thinning produce similar PEC signals, making signal interpretation very difficult. This paper describes time-frequency analysis algorithms applied to pulsed-eddy current signals from lap-joint specimens containing simulated flaws. The effect of probe lift-off, interlayer gap, and material thinning on PEC signals is examined in three-dimensional space (amplitude-time-frequency). This study shows that the time-frequency analysis of PEC signals provides specific visual patterns that can be related to the interlayer gap, lift-off, and material loss.
引用
收藏
页码:73 / 86
页数:14
相关论文
共 12 条
[1]  
Bieber JA, 1998, REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, P315
[2]  
CLAASEN TACM, 1980, PHILIPS J RES, V35, P372
[3]  
CLAASEN TACM, 1980, PHILIPS J RES, V35, P217
[4]  
CLAASEN TACM, 1980, PHILIPS J RES, V35, P276
[5]   Determination of the group and phase velocities from time-frequency representation of Wigner-Ville [J].
Latif, R ;
Aassif, EH ;
Maze, G ;
Moudden, A ;
Faiz, B .
NDT & E INTERNATIONAL, 1999, 32 (07) :415-422
[6]  
LEPINE BA, 1998, P 1 PAN AM C NOND TE, P107
[7]  
MCINTIRE P, 1982, NONDESTRUCTIVE TESTI
[8]  
Qidwai U, 1999, INSIGHT, V41, P700
[9]  
SAFIZADEH MS, 1999, EPMRT9908
[10]  
Ville J., 1948, CABLES TRANSMISSIONS, V2, P61