Assessment of atrial septal defect morphology by transthoracic three dimensional echocardiography using standard grey scale and Doppler myocardial imaging techniques: comparison with magnetic resonance imaging and intraoperative findings

被引:37
作者
Lange, A
Walayat, M
Turnbull, CM
Palka, P
Mankad, P
Sutherland, GR
Godman, MJ
机构
[1] WESTERN GEN HOSP,DEPT RADIOL,EDINBURGH EH4 2XU,MIDLOTHIAN,SCOTLAND
[2] UNIV EDINBURGH,ROYAL HOSP SICK CHILDREN,DEPT CARDIOL,EDINBURGH,MIDLOTHIAN,SCOTLAND
关键词
atrial septal defect; morphology; three dimensional echocardiography; magnetic resonance imaging;
D O I
10.1136/hrt.78.4.382
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To determine whether transthoracic three dimensional echocardiography is an accurate non-invasive technique for defining the morphology of atrial septal defects (ASD). Methods-In 34 patients with secundum ASD, mean (SD) age 20 (17) years (14 male, 20 female), the measurements obtained from three dimensional echocardiography were compared to those obtained from magnetic resonance imaging (MRT) or surgery. Three dimensional images were constructed to simulate the ASD view as seen by a surgeon. Measured variables were: maximum and minimum vertical and horizontal ASD dimension, and distances to inferior and superior vena cava, coronary sinus, and tricuspid valve. In each patient two ultrasound techniques were used to acquire three dimensional data: standard grey scale imaging (GSI) and Doppler myocardial imaging (DMI). Results-Good correlation was found in maximum ASD dimension (both horizontal and vertical) between three dimensional echocardiography and both MRI (GSI r = 0.96, SEE = 0.05 cm; DMI r = 0.97, SEE = 0.04 cm) and surgery (GSI r = 0.92, SEE = 0.06 cm; DMI r = 0.95, SEE = 0.06 cm). The systematic error was similar for both three dimensional techniques when compared to both MRI (GSI = 0.40 cm (27%); DMI = 0.38 cm (25%)) and surgery (GSI = 0.50 cm (29%); DMI = 0.37 cm (22%)). A significant difference was found in both horizontal and vertical ASD dimension changes during the cardiac cycle. This change was inversely correlated with age. These findings were consistent for both DMI and GSI technique. In children (age less than or equal to 17 years), the feasibility of detecting structures and undertaking measurements was similar for both echo techniques. However, in adult ASD patients (age greater than or equal to 18 years) this feasibility was higher for DMI than for GSI. Conclusions-Transthoracic three dimensional imaging using both GSI and DMI accurately displayed the varying morphology, dimensions, and spatial relations of ASD. However, DMI was a more effective technique than GSI in describing ASD morphology in adults.
引用
收藏
页码:382 / 389
页数:8
相关论文
共 32 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
AZEVEDO J, 1996, J AM COLL CARDIOL S, V27, P901
[3]   3-DIMENSIONAL ULTRASOUND IMAGING OF THE ATRIAL SEPTUM - NORMAL AND PATHOLOGICAL ANATOMY [J].
BELOHLAVEK, M ;
FOLEY, DA ;
GERBER, TC ;
GREENLEAF, JF ;
SEWARD, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (06) :1673-1678
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   ECHOCARDIOGRAPHIC FOLLOW-UP OF ATRIAL SEPTAL-DEFECT AFTER CATHETER CLOSURE BY DOUBLE-UMBRELLA DEVICE [J].
BOUTIN, C ;
MUSEWE, NN ;
SMALLHORN, JF ;
DYCK, JD ;
KOBAYASHI, T ;
BENSON, LN .
CIRCULATION, 1993, 88 (02) :621-627
[6]   VIDEO-ASSISTED CARDIOSCOPY IN CONGENITAL HEART OPERATIONS [J].
BURKE, RP ;
MICHIELON, G ;
WERNOVSKY, G .
ANNALS OF THORACIC SURGERY, 1994, 58 (03) :864-868
[7]  
CHAN KC, 1993, BRIT HEART J, V69, P52
[8]   EXPERIMENTAL ATRIAL SEPTAL-DEFECT CLOSURE WITH A NEW, TRANSCATHETER, SELF-CENTERING DEVICE [J].
DAS, GS ;
VOSS, G ;
JARVIS, G ;
WYCHE, K ;
GUNTHER, R ;
WILSON, RF .
CIRCULATION, 1993, 88 (04) :1754-1764
[9]  
DICKINSON DF, 1981, BRIT HEART J, V46, P55
[10]   ATRIAL-LEVEL SHUNTS - SENSITIVITY AND SPECIFICITY OF MR IN DIAGNOSIS [J].
DIETHELM, L ;
DERY, R ;
LIPTON, MJ ;
HIGGINS, CB .
RADIOLOGY, 1987, 162 (01) :181-186