Coil occlusion of the small patent arterial duct without arterial access

被引:9
作者
Anil, SR [1 ]
Sivakumar, K [1 ]
Kumar, RK [1 ]
机构
[1] Amrita Inst Med Sci & Res Ctr, Div Pediat Cardiol, Kochi 682026, Kerala, India
关键词
Gianturco coils; transcatheter intervention; patent arterial duct;
D O I
10.1017/S1047951102000094
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background., Arterial access is traditionally considered mandatory during coil occlusion of the patent arterial duct. Arterial access necessitates heparinization and carries the risk of femoral artery occlusion in small children. Methods and Results: Between July 1999 and May 200 1, we attempted coil occlusion of patent arterial ducts in 104 patients without arterial access. The patients were aged from 3 months to 14 years. The median age was 2 years, They weighed 3-35 kg. The median weight was 9.8 kg. The duct diameter at pulmonary artery insertion was 1.8-3.5 mm. The patients were selected on basis of echocardiographic evaluation of duct diameter at pulmonary artery insertion and morphology of the ampulla. Doppler color flow imaging was used in the catheterization laboratory to confirm duct closure. Arterial access was required in 21 patients. The reasons included accidental puncture in 5 patients, failure to obtain venous access in I patient, aortic embolization in 3 patients, poor echo images in 2 patients, requirement for additional coils in, 8 patients and, failure to cross the duct from pulmonary artery in 2 patients. The fluoroscopic time ranged from 2.2 to 20 min with a mean of 5.3 +/- 3.8 min. Immediate closure was achieved in 98 patients and this included 79 of the 83 patients in whom arterial access was avoided, Color Doppler 3-24 h later showed residual flow in 2 patients. Four patients had new-onset left pulmonary artery turbulence with peak- gradients below 5 mm of mercury. Coil embolization occurred in 6 patients and all coils were retrieved. Three-month follow up information was available for 78 patients. Small residual ductal leaks were seen in 4 patients, 2 of whom had leaks at 24 h. Two patients had recanalized their ducts. Conclusion: It is feasible to occlude small patent arterial ducts with coils using venous access alone in carefully selected patients with excellent immediate and short-term results.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 14 条
[1]   COMPLICATIONS OF PEDIATRIC CARDIAC-CATHETERIZATION - A 3-YEAR STUDY [J].
CASSIDY, SC ;
SCHMIDT, KG ;
VANHARE, GF ;
STANGER, P ;
TEITEL, DF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (06) :1285-1293
[2]  
Celiker A, 1997, EUR HEART J, V18, P450
[3]  
DeMoor M, 1996, S AFR MED J, V86, pC143
[4]   Mechanical occlusion of the patent ductus arteriosus with Jackson coils [J].
El Sisi, A ;
Tofeig, M ;
Arnold, R ;
Peart, I ;
Kitchiner, DJ ;
Bu'Lock, FA ;
Walsh, KP .
PEDIATRIC CARDIOLOGY, 2001, 22 (01) :29-33
[5]   USE OF HEPARINIZATION TO PREVENT ARTERIAL THROMBOSIS AFTER PERCUTANEOUS CARDIAC-CATHETERIZATION IN CHILDREN [J].
FREED, MD ;
KEANE, JF ;
ROSENTHAL, A .
CIRCULATION, 1974, 50 (03) :565-569
[6]   Transcatheter closure of the patent ductus arteriosus: Comparison between the Rashkind occluder device and the anterograde Gianturco coils technique [J].
Galal, O ;
deMoor, M ;
AlFadley, F ;
Hijazi, ZM .
AMERICAN HEART JOURNAL, 1996, 131 (02) :368-373
[7]  
Galal O, 1997, EUR HEART J, V18, P625
[8]   RESULTS OF ANTEROGRADE TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS USING SINGLE OR MULTIPLE GIANTURCO COILS [J].
HIJAZI, ZM ;
GEGGEL, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (09) :925-929
[9]  
Huang TC, 2000, CATHETER CARDIO INTE, V50, P334, DOI 10.1002/1522-726X(200007)50:3<334::AID-CCD13>3.0.CO
[10]  
2-M