CT fluoroscopy-guided abdominal interventions: Techniques, results, and radiation exposure

被引:183
作者
Silverman, SG
Tuncali, K
Adams, DF
Nawfel, RD
Zou, KH
Judy, PF
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Hlth Care Policy, Boston, MA 02115 USA
关键词
abdomen; interventional procedures; abscess; drainage; biopsies; technology; computed tomography (CT); guidance; fluoroscopy; radiations; exposure to patients and personnel;
D O I
10.1148/radiology.212.3.r99se36673
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the benefits; of computed tomographic(CT) fluoroscopy guided interventions and assess radiation exposures incurred With CT fluoroscopy. MATERIALS AND METHODS: A 6-month period of use of CT fluoroscopy to guide abdominal biopsy-procedures and catheter drainage was analyzed. Efficacy measures and needle placement and procedure room times were compared with those of the preceding 6 months during which conventional CT was used. CT fluoroscopic times and estimated radiation exposures were compared for two CT fluoroscopic methods. RESULTS: The sensitivity and negative predictive values for biopsy procedures and the success rate for needle aspiration or catheter drainages for CT fluoroscopy-98%, 86%, and 100%, respectively-were not significantly different from those for conventional CT-95%, 80%, and 97%, respectively. Room time was not reduced significantly, but mean needle placement time for CT fluoroscopy (29 minutes; n = 95) was significantly lower than that for conventional CT (36 minutes; n = 93; P <.005). The mean patient dose index was 74 cCy. Limiting CT fluoroscopy to scanning the needle tip rather than scanning the entire needle pass significantly reduced the dose to the patient and the operator. CONCLUSION: Although CT fluoroscopy is a useful targeting technique, significant radiation exposures may result. Therefore, radiologists need to be aware of different methods of CT fluoroscopic guidance and the factors that contribute to radiation exposure.
引用
收藏
页码:673 / 681
页数:9
相关论文
共 23 条
[1]  
DALY BD, 1997, RADIOLOGY P, V205, P374
[2]   Real-time CT-fluoroscopy for guidance of percutaneous drainage procedures [J].
Froelich, JJ ;
Saar, B ;
Hoppe, M ;
Ishaque, N ;
Walthers, EM ;
Regn, J ;
Klose, KJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (05) :735-740
[3]   GUIDED PERCUTANEOUS BIOPSY OF INTRAABDOMINAL LESIONS [J].
GAZELLE, GS ;
HAAGA, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (05) :929-935
[4]  
GIANFELICE D, 1998, AJR S, V170, P80
[5]   PRECISE BIOPSY LOCALIZATION BY COMPUTED TOMOGRAPHY [J].
HAAGA, JR ;
ALFIDI, RJ .
RADIOLOGY, 1976, 118 (03) :603-607
[6]  
Kalender WA., 1997, Radiology, V205, P471
[7]  
KATADA K, 1995, RADIOLOGY, V197, P494
[8]   Guidance with real-time CT fluoroscopy: Early clinical experience [J].
Katada, K ;
Kato, R ;
Anno, H ;
Ogura, Y ;
Koga, S ;
Ida, Y ;
Sato, M ;
Nonomura, K .
RADIOLOGY, 1996, 200 (03) :851-856
[9]  
KATADA K, 1994, RADIOLOGY S, V193, P339
[10]  
Katada K, 1994, RADIOLOGY, V190, P662