Alignment of dynamic cardiac PET images for correction of motion

被引:25
作者
Turkington, TG
DeGrado, TR
Hanson, MW
Coleman, RE
机构
[1] Department of Radiology, Duke University Medical Center, Durham
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.568814
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A technique was developed to align images from dynamic cardiac N-13 ammonia positron emission tomography (PET) scans, Inaccurate alignment of images from these scans stems from breathing, motion of the heart within the thorax, and overall motion of the patient (particularly during pharmacologic stress), The images from these scans represent changing distributions, from high blood pool concentrations to predominantly myocardial uptake, and are generally noisy, In this technique, templates are defined from a long, late frame (5-10 min), These templates include a myocardial template, which matches late frames, a blood pool template, which matches frames in which the left ventricle blood pool is dominant, and a modified blood pool template, which reduces the effect of activity in the right ventricle. The correlation function is used as the maximized parameter over shifts between each three-dimensional image frame and the appropriate template, The technique was tested on phantom, human, and animal data with myocardial defects, Phantom data showed the technique to be reliable to within one voxel (1.7 x 1.7 x 4.2 mm(3)), and motion which was apparent in human data was reduced significantly, Blood flow values measured from corrected data showed two traits: higher values, due to better matching regions of interest to images, and better fits, due to smoother time-activity curves.
引用
收藏
页码:235 / 242
页数:8
相关论文
共 14 条
[1]  
BACHARACH SL, 1993, J NUCL MED, V34, P311
[2]  
DEGRADO TR, 1994, J NUCL MED, V35, P1398
[3]  
EISNER RL, J NUCL MED, V28, P97
[4]   SPATIAL AND TEMPORAL REGISTRATION OF CARDIAC SPECT AND MR-IMAGES - METHODS AND EVALUATION [J].
FABER, TL ;
MCCOLL, RW ;
OPPERMAN, RM ;
CORBETT, JR ;
PESHOCK, RM .
RADIOLOGY, 1991, 179 (03) :857-861
[5]  
HOH CK, 1993, J NUCL MED, V34, P2009
[6]   NONINVASIVE QUANTIFICATION OF REGIONAL BLOOD-FLOW IN THE HUMAN HEART USING N-13 AMMONIA AND DYNAMIC POSITRON EMISSION TOMOGRAPHIC IMAGING [J].
HUTCHINS, GD ;
SCHWAIGER, M ;
ROSENSPIRE, KC ;
KRIVOKAPICH, J ;
SCHELBERT, H ;
KUHL, DE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (05) :1032-1042
[7]   N-13 AMMONIA MYOCARDIAL IMAGING AT REST AND WITH EXERCISE IN NORMAL VOLUNTEERS - QUANTIFICATION OF ABSOLUTE MYOCARDIAL PERFUSION WITH DYNAMIC POSITRON EMISSION TOMOGRAPHY [J].
KRIVOKAPICH, J ;
SMITH, GT ;
HUANG, SC ;
HOFFMAN, EJ ;
RATIB, O ;
PHELPS, ME ;
SCHELBERT, HR .
CIRCULATION, 1989, 80 (05) :1328-1337
[8]   QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW USING N-13 AMMONIA AND REORIENTED DYNAMIC POSITRON EMISSION TOMOGRAPHIC IMAGING [J].
KUHLE, WG ;
PORENTA, G ;
HUANG, SC ;
BUXTON, D ;
GAMBHIR, SS ;
HANSEN, H ;
PHELPS, ME ;
SCHELBERT, HR .
CIRCULATION, 1992, 86 (03) :1004-1017
[9]  
MUZIK O, 1993, J NUCL MED, V34, P336
[10]   SPATIAL REGISTRATION OF ECHOCARDIOGRAPHIC AND POSITRON EMISSION TOMOGRAPHIC HEART STUDIES [J].
SAVI, A ;
GILARDI, MC ;
RIZZO, G ;
PEPI, M ;
LANDONI, C ;
ROSSETTI, C ;
LUCIGNANI, G ;
BARTORELLI, A ;
FAZIO, F .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (03) :243-247