Characterization of an improved electrodynamic ion funnel interface for electrospray ionization mass spectrometry

被引:141
作者
Shaffer, SA [1 ]
Tolmachev, A [1 ]
Prior, DC [1 ]
Anderson, GA [1 ]
Udseth, HR [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1021/ac990346w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved electrodynamic ion funnel for ion focusing at high pressure (>1 Torr) has been developed for a triple quadrupole mass spectrometer and its performance compared with that of an earlier prototype previously reported. The ion funnel consists of a series of ring electrodes of progressively smaller interval diameters to which rf and de electric potentials are co-applied, The new design utilizes ring electrodes possessing larger internal diameters that taper down to a relatively larger exit aperture. in the 1-10 Torr pressure range, the new design provides significant improvement in low m/z ion transmission. Additionally, the overall ion transmission range is improved by linked scanning of the ion funnel's rf voltage concomitantly with the scanning of the quadrupole mass analyzer. Transmission of a noncovalent complex through the interface demonstrated that excessive ion heating was not problematic. Computer simulations of ion transport support the ion funnel design and help explain the relative performance of both designs. Both ion simulations and experimental results are in accord and indicate close to 100% ion transmission efficiency for electrosprayed biopolymer ions through the interface and into the mass analyzer.
引用
收藏
页码:2957 / 2964
页数:8
相关论文
共 18 条
[1]  
BAHR R, 1969, E VERH DTSCH PHYS GE, V4, P343
[2]  
Burlingame AL, 1998, ANAL CHEM, V70, p647R
[3]   Collision cross sections of myoglobin and cytochrome c ions with Ne, Ar, and Kr [J].
Chen, YL ;
Collings, BA ;
Douglas, DJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (07) :681-687
[4]  
Dehmelt H., 1967, ADV ATOM MOL PHYS, V3, P53, DOI DOI 10.1016/S0065-2199(08)60170-0
[5]  
Dodonov A, 1997, RAPID COMMUN MASS SP, V11, P1649, DOI 10.1002/(SICI)1097-0231(19971015)11:15<1649::AID-RCM67>3.0.CO
[6]  
2-T
[7]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408
[8]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[9]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[10]  
GERLICH D, 1992, ADV CHEM PHYS, V82, P1