Adhesion performance of UHMWPE after different surface modification techniques

被引:114
作者
Oosterom, R
Ahmed, TJ
Poulis, JA
Bersee, HEN
机构
[1] Delft Univ Technol, Fac Aerosp Engn, NL-2629 HS Delft, Netherlands
[2] Delft Univ Technol, Adhes Inst, NL-2629 HS Delft, Netherlands
关键词
joint replacement; fixation; UHMWPE; adhesion; surface modification;
D O I
10.1016/j.medengphy.2005.07.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel design of an ultra-high molecular weight polyethylene (UHMWPE) glenoid component has been proposed, based on adhesion to PMMA bone cement. However, due to the non-polar nature of UHMWPE, surface modification techniques are needed to obtain good adhesion and thus for the design to be viable. The aim of the study is to investigate adhesion of UHMWPE after different surface treatments. Three gas-phase surface modification techniques were investigated, namely UV/Ozone, corona discharge and radio frequency glow discharge plasma, as well as abrasion. The surface treated samples were examined using water contact angle, surface energy and roughness measurements, as well as single lap-joint shear testing using polymethylmethacrylate (PMMA) bone cement and methylmethacrylate (MMA) adhesive. The effect of aging on bonded samples has also been investigated. Corona and glow discharge treatments were found to activate the surface as shown by an increase in surface energy of over 100% in an order of less than a minute. corresponding to an increase in ultimate shear stress from 0.12 to 0.40MPa. In contrast, UV/Ozone required exposure times in the order of minutes to have an effect that was still incomparable to the other gas-phase treatments examined. Abrasion produced slightly better adhesion properties for single lap-joints bonded with PMMA compared to the corona treatment. The best treatment was found to be a combined treatment of surface roughening for 10 s, and subsequently a 90 s glow discharge treatment, resulting in failure of the UHMWPE sheet material. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:323 / 330
页数:8
相关论文
共 26 条
[1]   Loosening performance of cemented glenoid prosthesis design pairs [J].
Anglin, C ;
Wyss, UP ;
Nyffeler, RW ;
Gerber, C .
CLINICAL BIOMECHANICS, 2001, 16 (02) :144-150
[2]  
[Anonymous], 1999, Adhesion Promotion Techniques: Technological Applications
[3]   Reimplantation of a glenoid component after component removal and allograft bone grafting: A report of 3 cases [J].
Antuna, S ;
Sperling, JW ;
Cofield, RH .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (06) :637-641
[4]   Plasma-surface modification of biomaterials [J].
Chu, PK ;
Chen, JY ;
Wang, LP ;
Huang, N .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2002, 36 (5-6) :143-206
[5]   Corona, spark and combined UV and ozone modification of polymer films WeBP23 [J].
Friedrich, J ;
Wigant, L ;
Unger, W ;
Lippitz, A ;
Wittrich, H .
SURFACE & COATINGS TECHNOLOGY, 1998, 98 (1-3) :879-885
[6]   Ipsilateral total shoulder and elbow arthroplasties in patients who have rheumatoid arthritis [J].
Gill, DRJ ;
Cofield, RH ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (08) :1128-1137
[7]   Characterisation and comparison of industrially pre-treated homopolymer polypropylene, HF 135M [J].
Green, MD ;
Guild, FJ ;
Adams, RD .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2002, 22 (01) :81-90
[8]   FUNCTIONAL IMPROVEMENT AND COSTS OF HIP AND KNEE ARTHROPLASTY IN DESTRUCTIVE RHEUMATOID-ARTHRITIS [J].
JONSSON, B ;
LARSSON, SE .
SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 1991, 20 (05) :351-357
[9]  
Kinloch A. J., 1987, ADHES ADHES
[10]   Clinical results of the Mayo total ankle arthroplasty [J].
Kitaoka, HB ;
Patzer, GL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (11) :1658-1664