In this paper we present a new method of solving the inverse radiation treatment planning problem. The method is based on a Maximum Likelihood Estimator with dynamically changing penalization terms. The resulting Dynamically Penalized Likelihood (DPL) algorithm achieves a dose distribution of excellent uniformity in a tumor volume and a much lower dose in regions containing sensitive volumes. A simple model of a patient and of energy deposition has been used for the initial results presented: a two-dimensional computer generated phantom and monochromatic x rays, without scattering. Three two-dimensional problems are solved with the DPL algorithm, corresponding to different size and spatial relationships between the tumor and sensitive tissue volumes. The results show that the DPL algorithm is robust and flexible; it only requires moderate computation times and leads to promising solutions, even in rather difficult problems. The results encourage the extension of the present work to more realistic therapy situations. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1751 / 1764
页数:14
相关论文
共 20 条
[1]   OPTIMIZATION OF BEAM ORIENTATIONS IN RADIATION-THERAPY - SOME THEORETICAL CONSIDERATIONS [J].
BORTFELD, T ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02) :291-304
[2]   THE EXPONENTIAL RADON-TRANSFORM AND PROJECTION FILTERING IN RADIOTHERAPY PLANNING [J].
BORTFELD, TR ;
BOYER, AL .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (01) :62-70
[3]   A GENERALIZED PENCIL BEAM ALGORITHM FOR OPTIMIZATION OF RADIATION-THERAPY [J].
GUSTAFSSON, A ;
LIND, BK ;
BRAHME, A .
MEDICAL PHYSICS, 1994, 21 (03) :343-357
[4]  
Hildebrand F.B., 1974, INTRO NUMERICAL ANAL
[5]   AN ITERATIVE FILTERED BACKPROJECTION INVERSE TREATMENT PLANNING ALGORITHM FOR TOMOTHERAPY [J].
HOLMES, TW ;
MACKIE, TR ;
RECKWERDT, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (04) :1215-1225
[6]  
JOHNS HLE, 1969, PHYSICS RADIOLOGY
[7]   REPRESENTATION OF MEDICAL IMAGES BY VISUAL RESPONSE FUNCTIONS [J].
LLACER, J ;
ROMENY, BMT ;
FLORACK, LMJ ;
VIERGEVER, MA .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1993, 12 (01) :40-47
[8]   STATISTICAL-ANALYSIS OF MAXIMUM-LIKELIHOOD ESTIMATOR IMAGES OF HUMAN BRAIN FDG PET STUDIES [J].
LLACER, J ;
VEKLEROV, E ;
COAKLEY, KJ ;
HOFFMAN, EJ ;
NUNEZ, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :215-231
[9]   ITERATIVE TECHNIQUE FOR RECTIFICATION OF OBSERVED DISTRIBUTIONS [J].
LUCY, LB .
ASTRONOMICAL JOURNAL, 1974, 79 (06) :745-754
[10]   A GENERAL BAYESIAN IMAGE-RECONSTRUCTION ALGORITHM WITH ENTROPY PRIOR - PRELIMINARY APPLICATION TO HST DATA [J].
NUNEZ, J ;
LLACER, J .
PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1993, 105 (692) :1192-1208